33
For an Individual Window
To set the alarm properties for an individual window, right-click the mouse
on the window and select
Set Alarm
.
Module
/
Process Alarm Switch
:
to turn on the alarm setting, make sure
that both options are enabled (with checkmark).
Video Alarm Switch
:
to turn on / off the “no video” signal. You may set
the image border to the color
Red
, or to
Flash
, as warning.
GPO
:
to assign a GPO contact closure to alarm so that the alarm creates a
voltage (supports up to 5 V) on the contact when it is triggered.
All Process Response Time
:
to set the “no video” alarm response time
from
0.23
to
23
seconds.
Alarm Lock
:
once the signal is lost, and is re-gained, the warning will still
be shown on the screen. This feature is to notify you a problem happened
but no one noticed it right away.
Signal Type
:
sets the signal’s font and background color. When this
option is enabled, the video’s signal type will be displayed on the
monitor.