38
© 2009 Directed Electronics
Passive or Ignition controlled door locks operate
backwards.
•
This unit has easily-reversed lock/unlock outputs. Recheck Door
lock harness outputs (H3) section, to see if you have reversed
these.
The siren chirps/horn honks when the unit enters
panic mode, but the confirmation chirps/honks do
not work when locking and unlocking.
•
Are the confirmation chirps/honks turned on in programming?
See Feature Programming section.
•
Is the unit in Valet mode.
•
Is the horn pulse duration long enough? Some cars require a
longer pulse on the horn wire for it to honk. (see features pro-
gramming menu 1-11).
I can get into programming and change the feature
settings, but when I use the remote the settings
seem to change.
•
Are you using a binary, master dealer remote? Remember, you
can program the settings using a master dealer remote. However,
the unit will follow the dealer default settings when using a bina-
ry remote to operate the system.
Door Lock Learn Routine does not learn door locks.
•
Check connections to be sure everything is properly connected.
Refer to the
Keyless Entry Systems
-
Two Types
section of this guide.
•
Check the
Door Lock Learn Routine
section of this guide to ensure
the correct procedure is being used.
N3001L_2009-04print.qxd 5/12/2009 11:14 AM Page 38