9-13
9.3 MAINTAINING THE ADF
9.3.1 CLEAN THE ADF
The DS310F is designed to be maintenance free. However, it still
needs to be cleaned occasionally to ensure optimum image quality
and performance.
From time to time the pad assembly and feeding rollers may
become contaminated with ink, toner particles or paper dust. In this
case the DS310F may not feed documents smoothly. If this occurs
please follow the cleaning procedures to return your Scanner to its
original state.
The cleaning procedures:
1. Moisten a cotton swab with isoprophyl alcohol (95%).
2. Gently open the ADF front cover. Wipe the feeding rollers by
moving the swab from side to side. Rotate the rollers forward
with your finger and repeat the above cleaning procedures until
the rollers are clean. Be careful not to snag or damage the pick
springs.
3. Wipe the pad in the direction from top to bottom. Be careful not
to hook the pick springs.
4.
Close the ADF unit. Your Scanner is now ready for use.