43
AN-16/
i
v
.2 i
Nput
M
odule
u
ser
G
uide
Digital Snake - 48 x 16
To increase the digital snake to its maximum size using all four ports of the System Bridge, one more
AN-16/i v.2 is added on the stage connected to another AN-16/o Output Module at front-of-house.
Starting with the 32 x16 configuration described previously, make these connections:
On stage, make sure that the
1.
Slot Range switch is set to
1-16
on the AN-16/i v.2 being
added.
Connect the
2.
A-N
et
O
ut
of the AN-16/i v.2 Input Module to port
C
on the System Bridge.
At front-of-house, connect the
3.
A-N
et
I
N
of the AN-16/o Output Module to port
C
on the
System Bridge.
A
B
C
D
PRO16
PORTS
Cat-5 patching for the 48 x 16 configuration on stage
P
N
ote
The AN-16/i v.2 Input Modules shown in the preceding diagrams may be replaced with any