Reference
Entegra EX5000
-162-
600-00121-001 Rev 01
Check Oil Press
Engine Oil Pressure
outside limits.
Monitor oil pressure. If oil
pressure does not move
back into the green zone,
land as soon as possible.
Monitor oil pressure and
land as soon as possible.
Check ITT
Engine inter-turbine
temperature outside
limits.
Adjust power setting as
necessary to bring within
limits.
Engine Sensor Unit
is Not
Communicating
The MFD is not
receiving data from the
Engine Sensor Unit.
Use engine indicators on
PFD if available; Land as
soon as practical; have
aircraft serviced.
Electrical Sensor
Unit is Not
Communicating
The MFD is not
receiving data from the
Electrical Sensor Unit.
Land as soon as practical;
have aircraft serviced.
Fuel Quantity
Sensor Unit is Not
Communicating
The MFD is not
receiving data from the
Fuel Quantity Sensor
Unit.
Use fuel indicator on PFD if
available; Land as soon as
practical; have aircraft
serviced.
Rudder Trim Sensor
Unit is Not
Communicating
The MFD is not
receiving data from the
Rudder Trim Sensor
Unit.
Land as soon as practical;
have aircraft serviced.
Engine Sensor Unit
Configuration Error
The MFD has detected
a configuration error
between the MFD
settings and the
Engine Sensor Unit
configuration.
Have aircraft serviced
before flight.
Fuel Quantity
Indicator Not
Calibrated
The aircraft Fuel
Quantity sensors have
not been calibrated.
Ensure that Fuel Quantity
calibration is completed.
Torque Indicator Not
Calibrated
The aircraft Torque
Indicator sensor has
not been calibrated.
Ensure that Torque
Indicator calibration is
completed.
Table 12.17 Meridian Engine Messages (Continued)
Engine Messages &
Colors
Meaning
Recommended Pilot
Action
Содержание Entegra EX5000
Страница 1: ...600 00121 001 Rev 01 Entegra EX5000 ...
Страница 2: ...Entegra EX5000 600 00121 001 Rev 01 ...
Страница 8: ...Entegra EX5000 vi 600 00121 001 Rev 01 This page intentionally left blank ...
Страница 20: ...Introduction Entegra EX5000 6 600 00121 001 Rev 01 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 38: ...Map Page Entegra EX5000 24 600 00121 001 Rev 01 ...
Страница 44: ...Traffic Mode and the Traffic Page Entegra EX5000 30 600 00121 001 Rev 01 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 55: ...Using an ART 2000 or ART 2100 Radar 600 00121 001 Rev 01 41 Entegra EX5000 Figure 4 5 Vertical Profile View 5 ...
Страница 66: ...CMax Chart Pages Optional Entegra EX5000 52 600 00121 001 Rev 01 ...
Страница 84: ...CMax Chart Pages Optional Entegra EX5000 70 600 00121 001 Rev 01 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 91: ...600 00121 001 Rev 01 77 Entegra EX5000 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 92: ...Trip Page Entegra EX5000 78 600 00121 001 Rev 01 ...
Страница 96: ...Entegra EX5000 82 600 00121 001 Rev 01 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 187: ...Avionics Abbreviations 600 00121 001 Rev 01 173 Entegra EX5000 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 188: ...Reference Entegra EX5000 174 600 00121 001 Rev 01 ...
Страница 198: ...Entegra EX5000 184 600 00121 001 Rev 01 This page intentionally left blank ...
Страница 199: ......