EX5000 Installation Manual
P/N 600-00073 Rev 24
- 72 -
6.
Once all points have been calibrated, press
Calibration Complete
. The calibration factors are
computed and applied to DAU reported fuel quantity.
7.
When you are done, press
Save
. Press
Cancel
to exit without saving changes.
8.
Changes do not take effect until the MFD has been restarted. From the Maintenance Mode Page,
press
Restart System
.
Other options from the Underway state are to
Restore Last Cal
and
Clear Cal
:
●
Press
Restore Last Cal
to restore the calibration values from the last completed calibration. The
calibration state is change to Calibrated.
●
Press
Clear Cal
to clear all calibration values. The state changes to Not Calibrated.
An
Are You Sure?
prompt gives you the chance to reconsider the decision to either restore or clear the
fuel calculations.
➥
Pressing
Cancel
from the Underway state causes the current calibration session to end without
saving any interim calibration values.
Note:
For the fuel calibration procedure for the 530-00170-000, 530-00180-000, 530-00195-000,
530-00195-001, 530-00195-010, and 530-00201-000 software, see the Piper Process
Specification document PPS60185.
Torque Calibration (Optional)
For some aircraft, the MFD provides an interface to the Torque Calibration feature. If this feature is
available, the
Torque Cal
button displays.
For information about using the Torque Calibration feature, see the factory procedures for the aircraft.
5.10.2 Engine Sensor Checkout
After restarting the MFD, view the Engine page to verify data communication. Operate the aircraft
engine to confirm correct operation of all sensors.
➥
The Percent Power function will not operate correctly on some models until the Aircraft Setup has
been completed.
Содержание 700-00004 Series
Страница 2: ......
Страница 4: ...EX5000 Installation Manual P N 600 00073 Rev 24 ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 10: ...EX5000 Installation Manual P N 600 00073 Rev 24 viii This page intentionally blank ...
Страница 40: ...EX5000 Installation Manual P N 600 00073 Rev 24 30 Figure 6 EX5000 Landscape Front View ...
Страница 92: ...EX5000 Installation Manual P N 600 00073 Rev 24 82 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 98: ...EX5000 Installation Manual P N 600 00073 Rev 24 88 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 104: ...EX5000 Installation Manual P N 600 00073 Rev 24 94 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 115: ...EX5000 Installation Manual P N 600 00073 Rev 24 105 Appendix J Wiring Diagram GPS FMS ...
Страница 117: ...EX5000 Installation Manual P N 600 00073 Rev 24 107 Appendix L Wiring Diagram Traffic Sensors ...
Страница 118: ...EX5000 Installation Manual P N 600 00073 Rev 24 108 Appendix M Wiring Diagram TAWS ...
Страница 119: ...EX5000 Installation Manual P N 600 00073 Rev 24 109 Appendix N Wiring Diagram Radar Sensor ...
Страница 120: ...EX5000 Installation Manual P N 600 00073 Rev 24 110 Appendix O Wiring Diagram Engine Sensors ...
Страница 121: ...EX5000 Installation Manual P N 600 00073 Rev 24 111 Appendix P Wiring Diagram Primary Flight Display PFD ...
Страница 126: ...EX5000 Installation Manual P N 600 00073 Rev 24 116 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 130: ...EX5000 Installation Manual P N 600 00073 Rev 24 120 This page intentionally left blank ...
Страница 131: ......