EX5000 Installation Manual
P/N 600-00073 Rev 24
- 61 -
➥
If using an ARINC 429 gyro, proceed to step Q.
K.
Calibrate 400 Hz REF GAIN
1.
Set the tilt table to 0
o
pitch and roll.
2.
Use the GAIN control to set the GAIN POT /2 setting between 28- and 30-.
3.
Set the 400 Hz REF field to 0.0 ±1.0
o
. To adjust the value:
◆
To increment the value of 400 Hz REF, use the right inner knob to change the TILT
SETTING to between 5 and 10 UP. When the TILT SETTING is set to between 5 and 10
UP, the value of he 400HzZ REF field will slowly increase.
◆
To decrement the value of 400 Hz REF, use the right inner knob to change the TILT
SETTING to between 5 and 10 DOWN. When the TILT SETTING is set to between 5 and
10 DOWN, the value of the 400HZzREF field will slowly decrease.
◆
When you reach the desired setting, quickly adjust the TILT SETTING to above 10 UP to
lock in the setting.
4.
Proceed to step L.
Note:
If the 400 Hz REF field is zero (0), and does not change when the TILT knob is adjusted,
check that the correct gyro has been selected when programming the Configuration Module.
L.
Calibrate PITCH GAIN
1.
Set the tilt table for 10
o
pitch up.
2.
Use the GAIN control to set the GAIN POT /2 setting to 25- or 26-.
3.
Set the PITCH ANGLE field to 10.0 ±1.0
o
.
◆
To increment the value of the PITCH ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 UP. When the TILT SETTING is set to between 5 and 10
UP, the value of the PITCH ANGLE field will slowly increase.
◆
To decrement the value of PITCH ANGLE, use the right inner knob to change the TILT
SETTING to between 5 and 10 DOWN. When the TILT SETTING is set to between 5 and
10 DOWN, the value of the PITCH ANGLE field will slowly decrease.
◆
When you reach the desired setting, quickly adjust the TILT SETTING to above 10 UP to
lock in the setting.
4.
Set for 10
o
PITCH DOWN. Repeat steps 2 and 3.
5.
Set the tilt table to 0
o
pitch and roll.
6.
Proceed to step M.
M.
Calibrate PITCH OFFSET
1.
Use the GAIN controls to set the GAIN POT /2 setting to 18- or 19-.
2.
Check that the tilt table is set for 0
o
pitch.
3.
Set the PITCH ANGLE field to 0.0 ±1.0
o
.
Содержание 700-00004 Series
Страница 2: ......
Страница 4: ...EX5000 Installation Manual P N 600 00073 Rev 24 ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 10: ...EX5000 Installation Manual P N 600 00073 Rev 24 viii This page intentionally blank ...
Страница 40: ...EX5000 Installation Manual P N 600 00073 Rev 24 30 Figure 6 EX5000 Landscape Front View ...
Страница 92: ...EX5000 Installation Manual P N 600 00073 Rev 24 82 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 98: ...EX5000 Installation Manual P N 600 00073 Rev 24 88 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 104: ...EX5000 Installation Manual P N 600 00073 Rev 24 94 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 115: ...EX5000 Installation Manual P N 600 00073 Rev 24 105 Appendix J Wiring Diagram GPS FMS ...
Страница 117: ...EX5000 Installation Manual P N 600 00073 Rev 24 107 Appendix L Wiring Diagram Traffic Sensors ...
Страница 118: ...EX5000 Installation Manual P N 600 00073 Rev 24 108 Appendix M Wiring Diagram TAWS ...
Страница 119: ...EX5000 Installation Manual P N 600 00073 Rev 24 109 Appendix N Wiring Diagram Radar Sensor ...
Страница 120: ...EX5000 Installation Manual P N 600 00073 Rev 24 110 Appendix O Wiring Diagram Engine Sensors ...
Страница 121: ...EX5000 Installation Manual P N 600 00073 Rev 24 111 Appendix P Wiring Diagram Primary Flight Display PFD ...
Страница 126: ...EX5000 Installation Manual P N 600 00073 Rev 24 116 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 130: ...EX5000 Installation Manual P N 600 00073 Rev 24 120 This page intentionally left blank ...
Страница 131: ......