TB6
Analogue Inputs/Outputs (Menu 7)
Specifications
Pin
Signal
1/2
AN O/P 1 and 2
Analogue outputs 1 and 2
Voltage (V) or Current (I) as selected by SW1
V or I: (11 bit + sign),
±
5% full scale accuracy,
update time 5 ms
V:
–10 V to +10 V,
≤
5 mA load
I:
–20 mA to +20 mA,
≤
500
Ω
load
3
AN GND
Analogue earth / ground for i/p and o/p
Connected to earth/ground internally
4/9
–10.5 V/+10.5V
Reference supplies for analogue inputs
Maximum Load: 5 mA, current limited
5/6
AN I/P 2 –/2 +
7/8
AN I/P 1 –/1 +
Differential analogue input 2
Differential analogue input 1
Voltage (V) or Current (I) as selected by SW1
V or I: (11 bit + sign),
±
5% full scale accuracy:
V:
–10 V to +10 V, 100 k
Ω
load input Z
I:
–20 mA to +20 mA, 235
Ω
load input Z
Common mode volts =
±
2.5 V maximum
TB5
Encoder/PTC (Menu 13)
Specifications
1
M_PTC
Input from motor PTC
Resistive: Trip:
Reset:
P2.13 (0
Ω
to 7 k
Ω
)
P2.13 – 0.1 k
Ω
2/5
FB –/FB+
Encoder power supply feedback for accurate
setting
4/6
+5 V/+24 V
Power supply outputs for the encoder
+5 V:
+24 V :
Adjustable, 350 mA maximum
4.5 - 6.5 V,
Fixed, 350 mA maximum
3
0 V
Common return line for encoder power supply
and the PTC
Connected to earth/ground internally
7/8
Z–/Z+
9 - 12
B–/B+, A–/A+
Marker signal from encoder
Encoder position signals
EIA RS422A, Max edge frequency 1.5 MHz
EIA RS422A, Max edge frequency 1.5 MHz
TB4
Communications
Specifications
1/2
RS485 Tx +/Tx–
3/4
RS485 Rx +/Rx–
Differential link for improved noise immunity
(Menu 32)
0 - 2 km range. Update time 10 ms.
5
GND
Common ground for communications links
Connected to earth / ground internally
6/7
No function
No connection
-
8/9
HSIO +/–
High speed digital link (Menu 20)
Common mode volts
≅
15 V
RS422 protocol,
±
signal differential wrt GND pin.
TB3
Digital Inputs (Menu 7)
Specifications
1
0 V (digital)
0 V reference of digital inputs
Connected to earth / ground internally
2 & 10 +24 V O/P
User supply for peripheral equipment
Volts range:
+22.8 V to +25.3 V
Max load:
500 mA
3 to 8
DIGIN 1-6
For remote control of drive – default functions are
shown in wiring diagram
Impedance:
15 k
Ω
Active:
+12 V to +50 V
Inactive:
Open circuit or
<
7 V
9
INTERLOCK
Hardware interlock – must be made to enable
drive
Impedance:
15 k
Ω
Healthy:
+12 V to +50 V
Unhealthy:
Open circuit or
<
7 V
TB2
Auxiliary Input Supply
Specifications
1
0 V Aux Input
2
+24 V Aux Input
Allows monitoring and programming with main
power switched off
Current, nominal ( CDC): 500 mA
Current, max (all versions): 2.2 A
TB1
Digital Outputs
Specifications
DIGOUT 1 to 3
Volt-free changeover relay outputs
Max volts:
250 Vac, 30 V d.c.
Max current:
3 A (resistive load)
Table 2–13. – User I/O Termination Panel Connections
2.5.2
Weight
The user I/O termination panel weighs approximately 1 kg (2.2 lb.).
Содержание MV3000 DELTA
Страница 1: ...T1689 Technical Manual Rev 07 MV3000 Air Cooled DELTA...
Страница 150: ...Maintenance T1689 Technical Manual Rev 07 Capacitor Reforming MV3000 Air Cooled DELTA Page 150 Page Intentionally Blank...
Страница 152: ...T1689 Technical Manual Rev 07 MV3000 Air Cooled DELTA Page 152 Page Intentionally Blank...
Страница 184: ...T1689 Technical Manual Rev 07 MV3000 Air Cooled DELTA Page 184 Page Intentionally Blank...