System Director
16
•
List of users and groups within the system
•
Identity of all System Directors in the system (if you have more than one System Director)
Avid ISIS assures media protection and availability using the following techniques:
•
Mirrored system drives are used for system operation and System Director metadata storage.
•
A failed system drive can be replaced without interrupting the operation of the Avid ISIS.
•
The 82 media drives are configured into eight RAID 6 groups with two drives reserved as
hot spares. If any of the RAID drives fail, the Avid ISIS automatically uses the spare drive to
rebuild the RAID group. The failed drive can be removed and replaced with a new drive
without interrupting the operation of the Avid ISIS.
System Director Front Panel
The following figure shows the front view and control panel of the System Director.
System Director Front View
The following table describes the control panel shown in the previous figure.
System disk (ID 1)
System disk (ID 0)
ID
ID
Control panel
B
C
A
G
H
D
F
E
HALT RST
System Control Panel
Lette
r
Component
Description
A
Universal Serial Bus (USB)
port
USB 2.0 device port on the front of the system supports one USB
device. Recommended for use when re-imaging the system drives
or loading software. Two more USB ports are located on the back
of the system.
Содержание ISIS 2000
Страница 1: ...Avid ISIS 2000 Setup Guide...