Errors
113
Action:
Open the MOS Gateway configuration file. Edit the
<out_lower>
value in the
<tcpPorts>
group to insert a port number.
If there is no
<out_lower>
line, put one in the file. Stop and restart the
Router.
Error:
MOS Out Upper port(RO) did not exist in config file.
Location:
Event Log or Log file
Source:
MOS Gateway Router
Category:
Startup
Action:
Open the MOS Gateway configuration file. Edit the
<out_upper>
value in the
<tcpPorts>
group to insert a port number.
If there is no
<out_upper>
line, put one in the file. Stop and restart the
Router.
Warning:
roChannel was not found in the RoInfo data(
roInfoData
)
Location:
Log file
Source:
MOS Gateway Router
Category:
Miscellaneous
Action:
This is a warning only. There is a problem with the iNEWS Server
software. Call Avid Broadcast customer support with the
roInfoData
for
assistance.
Warning:
roInfo data(
roInfoData
) could not be loading into an XMLDOM
Location:
Log file
Source:
MOS Gateway Router
Category:
Miscellaneous