Appendix A
110
Category:
Startup
Action:
Ensure the MOS ConfigService is started.
Error:
MOS Gateway Logger cannot start: Cannot create
MOSConfiguration object.
Location:
Event Log
Source:
MOS Gateway Logger
Category:
Startup
Action:
Ensure the MOS ConfigService is started.
Error:
MOS Gateway Logger cannot start: Config file incomplete, the
<logging>
group must include
<directory>
,
<maxFileCount>
,
and
<maxFileBytes>
elements."
Location:
Event Log
Source:
MOS Gateway Logger
Category:
Startup
Action:
Open the MOS Gateway configuration file. Check that the
<logging>
group has three lines with tags:
<directory>
,
<maxFileCount>
, and
<maxFileBytes>
, each with a non-empty
value. Add one or more if necessary. Stop and restart the Router.
Error:
MOS Gateway Logger cannot start: Configuration file not found
Location:
Event Log
Source:
MOS Gateway Logger
Action:
Open the Registry Editor and navigate to the key
HKEY_LOCAL_MACHINE\SOFTWARE\Avid Technology\
MOSGateway
.