background image

AVG-PSU12-UL 

 

8.  Troubleshooting & Maintenance 

Problems 

Causes 

Solutions 

No output voltage  

Power supply protect function 
will start when over loaded. 

Please reduce loads. 

After selecting output voltage, 
the output channel will switch 
off automatically. 

Switch on the output channel via front 
panel button. 

Fail or loose connection 

Make sure the connection is good. 

AC1 

or 

AC2

 

indicator doesn’t 
work or respond 
to any operation 

Failed connection of the 
power cord. 

Make sure the power cord connection is 
good. 

Cannot control 
the device by 
control device 
(e.g. a PC) 
through RS232 
port 

Wrong RS232 
communication parameters 

Type in correct RS232 communication 
parameters. 

Fail or loose connection 

Make sure the connection is good. 

Broken RS232 port 

Send it to authorised dealer for checking. 

CMD ERR 

Extra characters like line feed or carriage 
return have been added to the 
command, remove them. 

Cannot control 
the device by 
front panel 
buttons while can 
control it through 
RS232 port 

The front panel buttons are 
broken 

Send it to authorised dealer for repair. 

Cannot control 
the device via 
GUI  

The IP address of control PC 
and TCP/IP port are not on 
the same network segment 

Modify control 

PC’s network segment to 

the same with the TCP/IP port. 

The port No. are wrong. 

The correct port No. is 4001. 

Fail or loose connection 

Make sure the connection is good. 

Broken TCP/IP port 

Send it to authorized dealer for checking. 

 

Содержание AVG-PSU12-UL

Страница 1: ...2 24V can be selected via the TACT switches on the rear panel RS232 or the GUI Sequential Control technology Supports online firmware updates The PSU12 UL is an integrated switching power supply designed for converting AC into DC power It features 2 input channels and 12 output channels input voltage 100 240VAC output 5 12 24VDC Using the built in sequential control technology when powered on the ...

Страница 2: ...ion instruction only and is not to be used in a maintenance capacity The functions described in this version are current as at October 2017 Any changes of functions and operational parameters will be updated in future manual versions Please refer to your dealer for the latest product details Version 1 0 23 10 17 ...

Страница 3: ...o extreme hot or cold temperatures 3 This unit will generate heat during operation please ensure that you allow adequate ventilation to ensure reliable operation 4 Please disconnect the unit from mains power if it will be left unused for a long period of time 5 Please DO NOT try to open the casing of the equipment DO NOT attempt to repair the unit Opening the unit will void the warranty There are ...

Страница 4: ...agram 4 2 Connection Procedure 4 3 System Applications 4 4 System Operations 5 Front Panel Control 5 1 RS232 Control 5 2 Installation Removal of the RS232 Control Software 5 2 1 Basic Settings 5 2 2 RS232 Communication Commands 5 2 3 GUI Control 5 3 Control Menu 5 3 1 Voltage Setting Menu 5 3 2 Netwrok Menu 5 3 3 Password Menu 5 3 4 GUI Update 5 3 5 Specifications 6 Panel Drawing 7 Troubleshooting...

Страница 5: ...hannels will turn on in sequence with a 100ms delay between In addition each output channel can be switched on off via the front panel 1 2 Features Dual input channel designed for ensuring a stable AC power source 12 Output channels each channel has three options for output voltage 5 12 24V Output channels can be switched on and off via the Front panel RS232 GUI and TCP IP Output voltage 5 12 24V ...

Страница 6: ... x Screws 4 x Rubber Feet 2 x Power Cords 12 x DC Power Cables 2 pin Phoenix Plugs 12 x 2 pin Phoenix Connectors 1 x 3 pin Phoenix Connector 1 x RS232 Cable DB9 to 3 pin Phoneix Connector 1 x User Manual Note Please immediately contact your distributor if you found any damage or defect in the components ...

Страница 7: ... is no power to the device Orange when the input voltage is too low or too high 01 12 Output channel switching buttons and activity LEDs 12 in total Press the button to turn the corresponding channel on or off The corresponding LED will change to green when the channel is on A long press for 3 seconds or more will lock unlock the channel the corresponding LED will flash 3 times Note Pictures shown...

Страница 8: ... factory settings C 5V 12V 24V indicators Green when the selected output voltage is working normally Blinking slowly when the current channel is closed Blinking fast when the current channel is in a short circuit state or over voltage RS232 Serial Port 3 pin Phoenix connector Connect your control device such as a 3rd party control system or PC TCP IP Ethernet port connect to your local network or ...

Страница 9: ...installed in a clean environment with temperature and humidity maintained to within equipment specifications All of the power switches plugs sockets and power cords should be insulated and safe All devices should be connected before power is turned on 4 2 Connection Diagram ...

Страница 10: ...tput voltage as 5V 12V or 24V Note After switching the output voltage the output channel will be turned off This is to protect an over voltage situation on the connected device Ensure your device is able to accept the selected voltage and turn the output on via the front panel Restore Factory defaults On the rear panel simultaneously long press SELECT on channel 1 and channel 2 for 3 seconds or mo...

Страница 11: ...he column Feedback Example is only for reference feedbacks may vary according to different operations and firmware System Commands Command Function Feedback Example All Switch on all outputs All Open All Switch off all outputs All Closed x Switch on the output channel x x 1 12 x Open x Switch off the output channel x x 1 12 x Closed Output x V y When y NULL Set the output voltage as x for all outp...

Страница 12: ... 12 12 12 12 12 12 12 12 12 Over N N N N N N N N N N N N Lock N N N N N N N N N N N N Clear x When x NULL clear the data of all the Groups Clear All When x 1 5 clear the data of the Group x Clear F x QueryGroup x When x NULL query all Groups Out 01 02 03 04 05 06 07 08 09 10 11 12 Vm1 12 12 12 12 12 12 12 12 12 12 12 12 Vm2 XX XX XX XX XX XX XX XX XX XX XX XX When x 1 5 query group x Out 01 02 03 ...

Страница 13: ...ocking all channel When x 1 12 lock channel x Locking x channel Unlock x When x NULL unlock all the channels Unlocking all channel When x 1 12 unlock channel x Unlocking x channel LockKeyboard x When x 0 unlock the front panel Unlocking Keyboard When x 1 lock the front panel Locking keyboard Rebootx When x NULL reboot all output ports When x 1 12 reboot the output port x Rebootx Note After sending...

Страница 14: ...68 0 178 the default IP address in your browser it will display the log in page as shown below 5 3 1 Control Menu Type the user name user password user and then click LOGIN it will display the Scene menu as shown below Select the ON OFF to switch on off the output channel Click the All On to switch on all output channels Click the All Off to switch off all output channels ...

Страница 15: ... Voltage setting menu as below Lock Unlock the output channel When the port is locked its voltage cannot be switched Select 5V 12V or 24V output voltage for each output channel 5 3 3 Network Menu Click Network to enter the network setting menu as below Dynamic or static IP addresses can be selected ...

Страница 16: ...ront Panel buttons 5 3 5 GUI Update GUI for the Power Switcher supports online update in http 192 168 0 178 100 Type the username and password the same as the GUI log in settings modified password will be available only after rebooting to log in the configuration interface After that click Administration at the source menu to get to the Upload Program as shown below ...

Страница 17: ...channel 5V 12W 12V 15W 24V 15W Maximum output power consumption for single supply 110VAC 90W 220VAC 180W Maximum output power consumption for dual supply 180W Control Part Buttons Control Front Panel 01 12 total 12 buttons Rear Panel Total 12 TACT Switches named SELECT RS232 Control RS232 port 3 Pin phoenix connector Baud rate support 9600 GUI Control TCP IP port RJ45 Default IP 192 168 0 178 Port...

Страница 18: ...RS232 TCP IP 24V AC100V 240V AC1 AC2 DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 437 mm 357 mm 44 mm ...

Страница 19: ... parameters Type in correct RS232 communication parameters Fail or loose connection Make sure the connection is good Broken RS232 port Send it to authorised dealer for checking CMD ERR Extra characters like line feed or carriage return have been added to the command remove them Cannot control the device by front panel buttons while can control it through RS232 port The front panel buttons are brok...

Отзывы: