The interface of the control software is shown below:
Set the parameters (baud rate, data bit, stop bit and parity bit) correctly to ensure
reliable RS232 control.
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
5.2.3 RS232 Communication Commands
1)
“[“, “]” in the commands are for easy recognition only and not necessary in real
operations. Other symbols including “.”, “,”, “/”, “%”, “;”, “^”. are parts of the
commands.
2)
The feedback listed in t
he column “Feedback Example” is only for reference,
feedbacks may vary according to different operations and firmware.
System Commands
Command
Function
Feedback Example
All@.
Switch on all outputs
All Open.
All$.
Switch off all outputs
All Closed.
[x]@.
Switch on the output channel [x], x = 1
– 12
[x] Open.
[x]$.
Switch off the output channel [x], x = 1
– 12
[x] Closed.
Output/[x]V/[y].
When y = NULL, Set the output voltage as x for all
output channels.
X = 5/12/24
All Output [x]V.
When y = 1 - 12, Set the output voltage as x for
the output channel y.
[y] Output [x]V.