5. System Operations
5.1 Front Panel Control
The front panel features four input and output selection buttons for switching the I/O
connection.
▪
Switch on/off output channel:
Press buttons
01
– 12
on the front panel to switch the corresponding output
channel.
▪
Lock/Unlock output channel:
Long press buttons
01
– 12
for 3 seconds or more on the front panel to
lock/unlock the corresponding channel. The corresponding LED will flash 3
times.
Note:
The locked channel can’t be controlled via the front panel buttons,
RS232 or the GUI.
▪
Select the Output Voltage:
Press
SELECT
on the corresponding output channel to select the output
voltage as 5V, 12V or 24V.
Note:
After switching the output voltage, the output channel will be turned off.
This is to protect an over voltage situation on the connected device. Ensure
your device is able to accept the selected voltage and turn the output on via
the front panel.
▪
Restore Factory defaults:
On the rear panel, simultaneously long press SELECT on channel 1 and
channel 2 for 3 seconds or more. The device will be restored to factory
settings.
5.2 RS232 Control
5.2.1 Installation/removal of RS232 Control Software
▪
Installation
Copy the control software file to the computer controlling the
Integrated Switching Power Supply.
▪
Removal
Delete all the control software files in corresponding file path.
5.2.2 Basic Settings
Here we use the software
CommWatch.exe
as an example. The icon is shown as
below
:
Icon of CommWatch