AVG-PSU12-UL
%9975.
Query the status of all output channels.
Out 01 02 03 04 05 06
07 08 09 10 11 12
State S S S S S S S S
S S S S
Vm 12 12 12 12 12 12
12 12 12 12 12 12
Over N N N N N N N N
N N N N
Lock N N N N N N N N
N N N N
/^Version;
Query the software version.
V x.x.x
Baud[x].
Set the baud rate as x. x = 1200, 2400, 4800,
9600, 19200, 38400, 57600 or 115200.
When x = NULL, the default baud rate is 9600.
Baud [x] not change.
Baud [y] change to [x]
Lock[x].
When x = NULL, lock all the channels.
Locking all channel.
When x = 1
– 12, lock channel x.
Locking [x] channel.
Unlock[x].
When x = NULL, unlock all the channels.
Unlocking all channel.
When x = 1
– 12, unlock channel x.
Unlocking [x] channel.
LockKeyboard[x].
When x = 0, unlock the front panel.
Unlocking Keyboard.
When x = 1, lock the front panel
Locking keyboard.
Rebootx.
When x = NULL, reboot all output ports;
When x = 1
– 12, reboot the output port x.
Rebootx.
Note:
▪
After sending the
“Output/[x]V/[y].”
to change the output voltage, the
corresponding output channel will be switched off, the command
“[x]@.”
can
be sent to turn the output back on.
▪
After sending the
“LockKeyboard[x].”
to lock the front panel, the device can
still be controlled by RS232 commands and GUI.