AVG-CS4K-88-V2
Command
Function
Feedback Example
Channel 3->1 Unlock!
…
Channel 8->1 Unlock!
Channel 1->2 Unlock!
Channel 2->2 Unlock!
….
Channel 8->8 Unlock!
CEC Commands (These commands below are shown for reference only, please contact
Avation for further specifics)
43 45 43 01 36 2E
Turn off the display devices.
43 45 43 01 44 6C
2E
43 45 43 01 04 2E
Turn on the display devices.
43 45 43 01 44 6D
2E
43 45 43 01 44 41
2E
Volume Up
43 45 43 01 44 42
2E
Volume Down
5.4 TCP/IP Control
Besides IR control and RS232 control, the Matrix Switcher boasts a TCP/IP port for
IP control.
Default settings: IP: 192.168.0.178; Subnet Mast: 255.255.255.0; Gateway:
192.168.0.1; Port: 4001.
The IP & gateway can be changed to suit network requirements, the Port cannot be
changed.
Connect the Ethernet port of the control device and the TCP/IP port of the Matrix
Switcher, and set same network subnet for the 2 devices, users are then able to
control the device via the web-based GUI or TCP/IP communication software.
5.4.1 Control Modes
The Matrix Switcher can be controlled by PC without Ethernet access or PC(s) within
a LAN.
Controlled by PC
Connect a computer to the TCP/IP port of the Matrix Switcher, and set its network
subnet to the same as the Matrix Switcher
’s.