![Avery Weigh-Tronix 7820-50 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/avery-weigh-tronix/7820-50/7820-50_user-instructions_3030597036.webp)
36
7800 Family User Instructions
Scale will not return to zero, or incorrect weight is displayed
1.
Press the
ZERO
key.
2.
Check for interference of weighing platform.
3.
Power off, remove all items from the platter, and then power on the scale.
4.
Recalibrate the scale.
5.
Replace the load cell.
6.
Replace the main board.
Display shows unrecognized characters
1.
Check software PROM for proper insertion.
2.
Check display cables for the proper connection.
3.
Replace PROM.
4.
Replace the display board.
5.
Replace the main board.
Display shows under _ _ _ _ _ dashes
(Indicates that the scale is below zero or under capacity.)
1.
Verify that weigh platter is on the scale.
2.
Press the
ZERO
key.
3.
Power off, remove any items from the platter, and then power on the scale.
4.
Recalibrate the scale.
5.
Replace the load cell.
6.
Replace the main board.
Display shows center - - - - - dashes
(Indicates that the scale is outside zero capacity of ±2%.)
1.
Verify that weigh platter is on the scale.
2.
Press the
ZERO
key.
3.
Power off, remove any items from the platter, and then power on the scale.
4.
Recalibrate the scale.
5.
Replace the load cell.
6.
Replace the main board.