7800 Family User Instructions
23
5.7
30.
Pres the
ZERO
key …
LOC-GR
is displayed. This stands for local gravity.
31.
Press the
TEST
key …
The current local gravity setting is displayed.
32.
Press the
ZERO
key …
CAL-GR
is displayed. This stands for calibration gravity.
33.
Press the
TEST
key …
The current calibration gravity settings is displayed.
34.
When you are finished, press the
ZERO
key, until
DONE
is displayed, then
press the
TEST
key to return to the top menu level …
DIAG
is displayed.
Or close Switch 1 to return to normal weighing mode.
5.7 Configuration Mode
The Configuration (CONF) mode menu allows scale configuration for your specific
application needs. The items you can configure are as follows:
FILTERING (FILT)
Choose between FAST and SLO filtering. SLO should be chosen
in areas susceptible to vibration. Choose FAST filtering for more
stable conditions.
Baud (BAUD)
.
Protocol (PROT)
Select the communication protocol to be used on the RS232 or
USB VCP port. Only one protocol and port can be used at a time.
NCI
NCI standard
8213
8213 compatible (Mettler-Toledo)
3835
NCI 3835
SMA
Scale Manufacturing Association
AUTO-1
Auto print operation (Type-1)
AUTO-2
Auto print operation (Type -2)
Manual print operation
PRTOUT
Choose an output data format from Table 3 for use with AUTO-1,
AUTO-2 or PRINT protocol selection.
Access the menu mode as described in
Accessing the Menu Mode on page 16
1.
From the
DIAG
display, press the
ZERO
key until
CONF
is displayed, or from
the normal weighing mode, move Switch 1 to the Menu Mode or the OPEN
position; then press the
ZERO
key until
CONF
is displayed.
2.
Press the
TEST
key …
FILT
is displayed.