5.10 Step-by-Step Instructions for CAL Mode
3.
Press the
ZERO
key to toggle between the choices. When the choice you want
is displayed, press the
TEST
key to accept …
The choice is accepted.
If
LBS
(lb) was selected, the scale will display
CLASS
.
If
1000G
(kg) was selected, scale displays the present capacity setting.
Proceed to Step
.
4.
Press the
ZERO
key to toggle between
SCALE
and
CLASS
. When the choice
you want is displayed, press the
TEST
key …
That choice is accepted and a scale capacity is displayed.
Example: 100.02
If a different capacity selection is desired, press the
ZERO
key to scroll
through the choices.
5.
When the desired capacity is displayed, press the
TEST
key …
That choice is accepted and
LOAD 0
is displayed.
6.
Clear all weight from the scale platter and press the
TEST
key …
After a brief wait LOAD xx is displayed. Alternate calibration points can
be chosen using the
ZERO
key to scroll between choices (see Table 1).
7.
Place the appropriate calibration weights on the scale and press the
TEST
key. After a brief wait …
DONE
is displayed.
8.
Remove all calibration weights from scale.
9.
Press the
TEST
key …
DIAG
is displayed, or return Switch 1 to the closed position. The scale
returns to normal weighing mode. The scale is now tested, configured,
and calibrated. It is ready for use in your application.
5.10 Gravity Mode
The Gravity Mode feature provides a means of adjusting the scale’s internal calibration
factors to compensate for variations in acceleration due to gravity at different
geographic locations. These differences can cause a given mass to indicate a slightly
different weight at an end-user’s (local) site than it did at the Calibration (CAL) site.
The capacity selected must correlate with the rated capacity of the scale noted on the
serial tag.
If this procedure is attempted without any calibration weights applied, the scale will
abort the process and retain the original calibration data.