Connections
4.2.2
OD Control sensor
Optional an OD control could be mounted to control the label roll. If the label material is nearly
empty the sensor gives an signal. A warning message and an output signal inform the personal
that in the next time the material has to be changed.
+24V
GND
14
black
green
white
red
brown
5
9
4
8
3
7
2
6
1
Signal-
GND
Supply
white
grey
blue
25
11
27
CN33
E3JK-R2M2
NPN sensor
5
9
4
8
3
7
2
6
1
Figure 9 NPN connection of optional ODC sensor
+24V
GND
14
black
green
white
red
brown
5
9
4
8
3
7
2
6
1
Signal-
GND
Supply
white
grey
blue
25
11
27
CN33
E3JK-R2M2
NPN sensor
5
9
4
8
3
7
2
6
1
Figure 10 PNP connection of optional ODC sensor