2.4 Environmental Requirements
Description
Specification
Operating Temperature
10° to 35° C (50° to 95° F), sea level
Non-operating Temperature
-40° to 60° C (-40° to 140° F)
Operating Relative Humidity
8% to 90% (noncondensing)
Non-operating Relative Humidity
5% to 95% (noncondensing)
Operating Elevation
0 to 2,000 m (0 to 6,562 ft.)
Ambient temperature is specified at sea level. For altitudes above sea
level, derate 1.0° C per 305 m, or 1.8° F per 1,000 ft., above sea level.
The maximum derated altitude is 2,000 m (6,562 ft.)
Non-operating Elevation
0 to 12,192 m (0 to 40,000 ft.)