11 Disposal
O
Comply with national regulations regarding disposal.
12 Troubleshooting
Table 13 contains an overview of malfunctions, possible causes, and remedies.
13 Technical Data
If you cannot remedy a malfunction, please contact AVENTICS GmbH. The
address is printed on the back cover of these instructions.
Table 13:
Table of malfunctions
Malfunction
Possible cause
Remedy
No output pressure
present
No power supply
Connect the power sup-
ply.
Check the polarity of the
power supply.
Switch on system com-
ponent.
No set point stipulated
Stipulate a set point.
No operating pressure
Connect the operating
pressure.
Output pressure too low
(less than the set point)
Operating pressure too low
Increase the operating
pressure.
A consumer with a high air
consumption is located in
the EV1X operating line and
results in a large pressure
drop in the device.
Reduce air consumption.
Operating pressure less
than 1 bar above the
maximum output pressure
to be controlled.
Adjust the operating
pressure to at least 1 bar
above the maximum
output pressure to be
controlled.
Air is audibly escaping
Seal is missing or damaged
Check the seals and re-
place, if necessary.
Pressure regulator is not
leaktight
Exchange the pressure
regulator
Pressure regulator
emits short pressure
pulses
Device with current input is
operated with voltage set
point
Stipulate the correct type
of set point
Outlet pressure jumps
to the level of the oper-
ating pressure
Set point too high
(> 20 mA or > 10 V)
Stipulate the correct set
point
Output pressure too
high
Dynamic pressure in ex-
haust
Check the exhaust line
DIAG LED illuminated
red
Parameter error
Stipulate valid parame-
terization
Safety cut-off active
Exchange device since a
pressure sensor is defec-
tive.
Table 14:
General data
General data
Dimensions
(width x height x depth)
EV12: 63 mm x 160 mm x 138.5 mm
EV18: 85 mm x 180 mm x 167 mm
Weight
EV12: 1.4 kg
EV18: 2.15 kg
Operating temperature
range
0
°
C to 50
°
C
Storage temperature
range
-25
°
C to 80
°
C
Ambient operating condi-
tions
Max. height above sea level: 2000 m
Version
Externally piloted pressure regulator
Permissible medium
Compressed air
Pneumatic connections
EV12: G1/2 and G3/8
EV18: G1 and G3/4
Max. particle size
50 μm
Oil content of compressed
air
0-5 mg/m
3
The pressure dew point must be at least 15°C below the ambient and medium
temperatures and must not exceed 3°C.
The oil content of compressed air must remain constant during the life cycle.
O
Use only the approved oils from AVENTICS, see the AVENTICS online catalog,
chapter “Technical information”.
Mounting orientation
Any if used with dry and oil-free compressed air
Protection class according
to EN 60529/IEC60529
IP65 (only when assembled and with all plugs
connected)
Relative humidity
95%, non condensing
Degree of contamination
2
Use
Only in closed rooms
Table 15:
Pneumatic data EV12 pressure regulator
Pneumatics
Flow rate values of the EV12 pressure regulator
Supply
pressure [bar]
Set pressure
[bar]
Output
pressure [bar]
Q [l/min]
Type L/R
Type C
11
10
9.8
3500
3500
11
10
9.0
4600
4600
7
6
5.8
2800
2800
7
6
5.0
3700
3550
Flow characteristic curves of EV12 pressure regulators type L and type R
Flow characteristic curves of EV12 pressure regulators type C
Table 16:
Pneumatic data EV18 pressure regulator
Pneumatics
Flow rate values of the EV18 pressure regulator
Supply pressure
[bar]
Set pressure [bar]
Output pressure
[bar]
Q [l/min]
Type L/R
10
8
8.8
9000
10
6
5.8
11000
10
4
3.8
15000
Flow characteristic curve of EV18 pressure regulator
Table 14:
General data
General data
[psi]
[bar]
10
8
7
6
5
4
3
2
1
0
0
1000
2000
3000
4000
5000
6000
7000
8000
[Nl/min]
9
145
116
101,5
87
72,5
58
43,5
29
14,5
0
130,5
P = 3 bar
v
P = 5 bar
v
P = 7 bar
v
P = 9 bar
v
P = 11 bar
v
P
a
=
outpu
t
p
ressure
P
v
= supply pressure (= output pr 1 bar)
[psi]
[bar]
10
8
7
6
5
4
3
2
1
0
9
145
116
101,5
87
72,5
58
43,5
29
14,5
0
130,5
0
1000
2000
3000
4000
5000
6000
7000
8000
[Nl/min]
P = 3 bar
v
P = 5 bar
v
P = 7 bar
v
P = 9 bar
v
P = 11 bar
v
P
a
=
outp
ut pressure
P
v
= supply pressure (= output pr 1 bar)
[psi]
[bar]
10
8
7
6
5
4
3
2
1
0
9
145
116
101,5
87
72,5
58
43,5
29
14,5
0
130,5
0
3000
6000
9000
12000
15000
18000
[Nl/min]
P
a
=
outp
ut pressure
P
v
= supply pressure = 10 bar
AVENTICS
| EV12/EV18 | R414011404–BAL–001–AA | English
21