User guide AMV 2125-DSP
page 10
4.2.3
Configuration
With config you have the possibility to decide with which preset and parameterset the program
will start when turned on. Further adjustments will be described below.
By pressing the „Preset“ dial you will enter to the Config-menu, when the little triangle is next
to “Config” (see below)
Now you can see the Startup-Preset starting the program on the display. By turning the
“Volume” dial you can change with which preset the program should start with (1-20).
By turning the “Preset” dial you will enter to the Startup-Parameterset-Menu. Here you can
select with which parameters the program should start with (1-4).
VU Out
: By turning the volume dial, you can choose which of the two outputs shall be shown
as VU-meters on the display.
LCD contrast
: Set the contrast of the LCD display from 0 to 50 for optimal readability.
Vol/Preset protect
: The protection of the settings is such that changes (e. g. changing
between presets or temporary volume changes) can only be performed while
pushing and
turning
the dials at the same time. This is intended to safeguard the settings from accidental
changes. If this protection is turned off, changes can be made by simply turning the dials
without pushing them. Turning the volume knob by one click either enables or disables the
protection.
Welcome screen Line 1
: Set the first line (16 characters) of the welcome text that shows up
when powering up the unit. The cursor will blink under the first character. By turning the
volume dial, the following letters, numbers, and special characters will appear in this order: A-
Z, Ä, Ö, Ü, a-z, ä, ö, ü, 0-
9, space, ! „ # $ % & ’ ( ) * + , - . / Pushing the preset dial will
confirm the current character und move the cursor one position to the right. Now you can set
the next character.
Welcome screen Line 2
: Set the second line (16 characters) of the welcome text that shows
up when powering up the unit.
Output 1 Name
: Determine the name of the first output. 8 characters are available for this
name (e.g. nave, gallery, etc.)
Output 2 Name
: same procedure as in Output Name 1
4.2.4
Utility
Inside this menu you have the possibility to copy a parameterset into another parameterset.
Turn the “Volume” dial until the small triangle is next to “Utility” and press the “Preset” dial.
Now you can see “Copy/Firmware” on the display. By pressing the dial again the following
menu will appear (see below)
By turning of the „Volume“ dial the source- and target parameterset for the copy process can
be determined. When the triangle is
on Copy, press the “preset” dial. Now the designated