• Connection nominal range: 30 m under normal conditions in a house (metal walls or anti-sei-
smic structures can reduce the range. Avoid their installation at less than 2 cm from the metal
walls).
Programming
1.
Turn on the power to the system: the LED 3 (green) will switch on.
2.
Press the internal reset push-button (Fig. 5) and the LEDs L1 (green) and L2 (red) will switch on
alternatively: the code learning sequence is carried out.
3.
Transmit the signal of “disconnected” from the control panel (control panel disconnected –OFF)
by turning the mechanical key or disconnecting the previously connected control panel by the
remote control.
NOTE:
Each time the mechanical key is turned or every time a disconnection is carried out by
means of the remote control, the control panel transmits the signal of “disconnected”.
4.
Once the system state indicator has received the signal “disconnected” from the control panel,
it stores the code linking it to the control panel and so it is ready to operate.
Operation
The device receives the signals of “connected”, “disconnected” and “alarm” from the control
panel and transmits the signals on the front panel as described below (see Fig. 5 for LED descrip-
tion).
Operation diagram
As the system state indicator needs a current between 8 and 24V dc or ac 50Hz, it can be instal-
led in parallel to the N.O. push-button which controls the door bell
(Fig. 6)
if this is an electrome-
chanical bell.
- 36 -
G
Fig. 6
electromechanical bell
LED
COLOUR
ON
OFF
FLASSHING
L1 (connected)
green
control panel connected
control panel disconnected
L2 (alarm)
red
no alarm
alarm
L3 (power)
green
power on
power off
C.369 31-05-2002 16:55 Pagina 36