NOTE: in order to guarantee 24 hours of operation to the system in the absence of power
supply, it is necessary not exceeding the value of maximum current demand, equal to 50 mA.
OPERATION
Connection-disconnection-partial connection
Connection, disconnection and partial connection of the system can be carried out as follows by
means of the remote control and only if the mechanical key is in the ON position. Move the key
to the PROG position to turn the system to the programming and TEST state.
- 25 -
G
FULL
CONNECTION
DISCONNECTION
PARTIAL
CONNECTION
Press the RED push-button of the remote control: all the Zone LEDs will
be turned on (A-B-C) and 3 beeps of confirmation will be heard. The
LEDs turn off once the exit time is passed, that is, after 60 seconds. At
the end of the exit time, the LED CONNECTED/ON turns on.
Press the GREEN push-button of the remote control before entering the
protected zone: you will hear a long beep for confirmation; the LEDs of
the channels which have stored alarms flash (some alarm devices repeat
the optical-sound signals which are typical of the ON/OFF operations).
The Zones A-B-C can be inserted individually as follows:
1. press the RED and GREEN push-buttons of the remote control
simul-
taneously
: the LEDs of the zone A (channels 1 and 2), zone B and
zone C flash progressively.
2. to disconnect the chosen zone, press the GREEN or the RED push-
button when their corresponding LED flashes. The end of this
sequence will be signalled by 3 beeps. The LEDs corresponding to
the connected zones remain on until the end of the output time.
Ordinary operation
The operation is possible only if the mechanical key is in the ON position. When turning the key
to the PROG position, all alarms and connection/disconnection operations are disconnected and
programming, maintenance and testing can now be carried out.
If the control panel is disconnected, the flashing leds indicate that the alarm has been stored. This
flashing lasts 30 seconds after disconnection and it can be restored each time you press the
GREEN push-button of the remote control.
When the system is subsequently connected, the stored alarms are cancelled by pressing the RED
push-button of the remote control.
Every time the system is connected, the reception of all signals coming from the zone intrusion
detectors is disconnected for 60 seconds (output time).
TEST State
By turning the mechanical key to the “Programming” position, the control panel automatically turns
to the TEST state. If it receives an alarm signal (transmitted by radio or by wire) it produces a beep
C.369 31-05-2002 16:55 Pagina 25