![Avaya Virtual Services Platform 7200 Series Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/avaya/virtual-services-platform-7200-series/virtual-services-platform-7200-series_installation-manual_3028206008.webp)
7254XSQ
Turn on Condition:
5–400 ms delay after application of AC power
Important:
The output rise time, from 10 to 90 percent, is 70 ms maximum and monotonic under all defined input
and output conditions.
Efficiency:
85 percent minimum
Table 4: 800 W AC power specifications
7254XTQ
Input Current:
9.9–4.79 A
Input Voltage (rms):
100–240 V, 47–63 Hz
Power Consumption:
800 W maximum
Thermal Rating:
2730 BTU/Hr maximum
Inrush Current:
40 A maximum
Turn on Condition:
1 second maximum after application of AC power
Important:
The output rise time, from 10 to 90 percent, is 50 ms maximum and monotonic under all defined input
and output conditions.
Efficiency:
70 percent minimum
AC power cord specifications
To connect AC power to the switch, you need an appropriate AC power cord as described in the
following table, also see the following table for plug specifications.
Table 5: International power cord specifications
Country and Plug Specification
Specifications
Typical Plug
Continental Europe:
• CEE7 standard VII male plug
• Harmonized cord (HAR marking on the outside of the cord
jacket to comply with the CENELEC Harmonized
Document HD-21)
• 220 or 230VAC
• 50 Hz
• Single phase
United States of America, Canada, and Japan:
• NEMA5-15P male plug
• UL-recognized (UL stamped on cord jacket)
• CSA-certified (CSA label secured to the cord)
• 100 or 120VAC
• 50–60 Hz
• Single phase
January 2015
Installation Job Aid for Avaya Virtual Services Platform 7200 Series
8