![Avaya Virtual Services Platform 7200 Series Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/avaya/virtual-services-platform-7200-series/virtual-services-platform-7200-series_installation-manual_3028206011.webp)
Note:
The chassis design prevents an incorrect installation of a power supply. If you insert a
power supply upside down, it will not fully insert.
Important:
The VSP 7200 does not have a power switch. When you connect the DC power source
to the DC power supply wiring assembly and then plug the DC power supply wiring
assembly into the DC power supply, the switch powers up immediately.
Warning:
Disconnecting the DC power supply wiring assembly from the power supply is the only
way to turn off DC power to the VSP 7200. Allow at least 30 seconds for the VSP 7200
to fully power down before restoring power. Otherwise, the VSP 7200 might produce a
core file during the reset leading to an extra delay during boot time.
4. Once you install a power supply, use the following steps to connect the DC power supply
wiring assembly:
a. Avaya supplies a DC power supply wiring assembly to connect the DC power supply to
the DC input power source.
b. Refer to the tag attached to the DC power supply wiring assembly to insert the cables
into their appropriate connectors.
Voltage:
Ensure that the positive and negative power inputs are connected to the correct
connectors and that the switch is properly grounded before connecting it to a power
source.
January 2015
Installation Job Aid for Avaya Virtual Services Platform 7200 Series
11