Choosing the Installation Site
Issue 3 February 2007
9
Choosing the Installation Site
Ensure that the location where you install your G250 fulfills the following requirements:
●
Cables are away from sources of electrical noise such as:
●
radio transmitters
●
broadcast amplifiers
●
power lines
●
fluorescent light fixtures
●
Water or moisture cannot enter the case of the chassis.
●
Air can flow freely around all sides of the chassis.
●
The vents on the sides of the case are not blocked.
●
The installation is no more than 16 feet (5 m) from an approved ground.
!
CAUTION:
CAUTION:
If the installation location is more than 16 feet (5 m) feet away from an approved
ground, do not install the Avaya G250 Media Gateway until a licensed electrician
is present to install a Supplementary Ground Conductor per Article 250 of the
National Electrical Code (NEC).
●
The environmental conditions match the requirements listed in
.
See Appendix A of
Installing and Upgrading the Avaya G250 Media Gateway
, 03-300434, for
additional information on environmental requirements.
Table 2: Environmental Requirements
Condition
Acceptable values
Ambient temperature
32
o
to 104
o
F (0
o
to 40
o
C)
Relative humidity
5% to 95%, non-condensing
Minimum clearance for
ventilation
2.5 in. (6.4 cm)
Weight support
22 lb. (10 kg)
Содержание G250 Series
Страница 1: ...Quick Start for Hardware Installation Avaya G250 Media Gateway 03 300433 Issue 3 February 2007 ...
Страница 10: ...Before you Start 10 Quick Start for Hardware Installation Avaya G250 Media Gateway ...
Страница 26: ...Power Up 26 Quick Start for Hardware Installation Avaya G250 Media Gateway ...
Страница 36: ...Prepare for Configuration 36 Quick Start for Hardware Installation Avaya G250 Media Gateway ...