Installing and Cabling the Cabinets
Set Ringing Option
66
Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
June 2004
Set Ringing Option
Figure 27: Ringing Option Selection
1
Check the ringing option for the country of installation (20 Hz, 25 Hz, or 50 Hz). See
Figure 27
.
2
Set the slide switch to the proper setting. Refer to the label on the side of the power unit.
Activate and Administer the System
NOTE:
The Avaya CMC1 Media Gateway is a PPN cabinet only. Cabinet A is the control carrier
and Cabinets B and C are port carriers.
Power Up System
Single Cabinet Installations
1
Insert the translation card into the slot in the TN2402 Processor circuit pack.
2
Fully seat the 650A Power Unit in the cabinet.
3
Set the circuit breaker at the AC load center to ON. This starts the system reboot process. In about
2 minutes, verify the screen displays:
Login:
Figure notes
1
Ringing option switch
evdmring LJK 062497
1