Upgrading R6csi/R7csi/R8csi to Avaya Communication Manager on an Avaya DEFINITY Server CSI
Task Table
166
Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
June 2004
3
Type neither
in the
Alarm Origination to OSS Numbers
field and press Enter.
NOTE:
Disabling alarm origination prevents the system from generating alarms, thus preventing
unnecessary trouble tickets.
For some DEFINITY ECS software versions, set the
Cleared Alarm Notification
and
Restart Notification
fields to disable before pressing Enter.
Check Link Status
1
Enter display communication-interface links and press Enter. Write down all enabled links
2
Type status link number and press Enter for each enabled link.
3
Write down which links are in service.
Save Translations
1
Type save translation and press Enter to write all translations from memory to the original
translation flashcard, which takes about 10 minutes.
When the save translations is successful, the error code must be a zero; otherwise, the translations
are not copied. If the translations were corrupted, the following error message displays when
logging in:
!
WARNING:
Translation corruption detected; call Avaya distributor immediately.
NOTE:
The save translation command cannot function if translations are corrupt. Refer to
Translation Corruption Detected
on page 334 to clear the problem.
Save Announcements (if necessary)
NOTE:
The TN750C and TN2501AP Integrated Announcement circuit packs store
announcements in nonvolatile memory; saving the announcements to a flashcard is
optional.
1
If the PPN contains a TN750/B Announcement circuit pack, type display announcements and
press Enter.
2
If administered recorded announcements are listed, type save announcements UUCSS and press
Enter. For example, 01D03. This takes about 30 minutes.
NOTE:
For some DEFINITY ECS software versions, type save announcements from UUCSS.
Type help and press Enter for complete command syntax.