Installation Manual
IMPORTANT!
All wires are evenly uncoiled
as shown in Fig. 5a to prevent
looping.
Fig. 5a
STOP
!
Guiding
Wire rope
Minimun safety
gap “S” all
around the
service lift:
1.9 in (50 mm)
Power Cable
Guiding
Wire rope
Traction
Wire rope
Safety
Wire rope
1.2 Wire positioning measurements
Fig. 6
Minimum shaft clearance
dimensions required for the service
lift to run, and distance between the
guide wires.
Dimensions:
Holes in the base platform in the tower for wire
bushing are positioned as outlined below.
1)
Standard wire rope guide/narrow wire rope guide.
The holes are positioned with a tolerance of +/-0.2 in (5 mm). Holes with diameter Ø7.9 in (Ø200
mm)
2)
are fitted with rubber edging.
2)
Note: Ø7.9 in (Ø200 mm) hole not needed in case traveling cable present.
DANGER!
Ensure that lift evacuation to the tower
ladder is possible.
Warning!
Ensure that no obstacles are in
the travel path of the service lift.
Shark
A
B
1)
C
D
E
S
L
9.8 in
250 mm
22.6/20.1 in
575/510 mm
37.8 in
960 mm
23.6 in
600 mm
8.9 in
220 mm
1.9 in
50 mm