User Manual
6
www.AvantcoEquipment.com
Rating Plate
Information on this plate includes the model, serial number, BTU/hour input of the burners, operating
gas pressure in inches WC, and whether the appliance is orificed for natural or propane gas. When
communicating with factory about a unit or requesting special parts or information, rating plate data
is essential for proper identification.
Recommendations Before Installation
Before installing the gas supply system, observe the pipes and fittings, check the components for
dirt, clean internally with compressed air to eliminate possible particles, and prevent burners and
valves from becoming clogged.
After cleaning, use thread sealant to connect the equipment to the gas network. For correct
application, avoid concentrating the compound on the first two threads of the pipe, otherwise it may
generate particles that will clog the system injectors.
Gas Standards & Codes
Installation of this appliance must be in accordance with local installation codes, including:
1.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system during any system pressure testing when this teste pressure exceeds 1/2 PSI (3.45 kPa).
2.
The appliance shall be isolated from the gas supply piping system by closing the manual shut-off
valve during any pressure test of the gas supply piping system at test pressures equal to or less
than 1/2 PSI (3.45 kPa).
GAS CONNECTION
The gas inlet line size of this appliance is 3/4” NPT. For proper operation, the gas supply line must be
the same size or larger. Gas line size should not be reduced at any point along the supply line.
MANUAL SHUTOFF VALVE
A gas pressure regulator and a shut-off valve supplied by the technician shall be installed in the gas service
line before the appliance - in a physical location where it can be reached quickly in an emergency.
!
IMPORTANT
FAILURE TO INSTALL THE PRESSURE REGULATOR WILL VOID YOUR WARRANTY.
Содержание 177CAG15MG
Страница 21: ...User Manual www AvantcoEquipment com 21 PARTS DIAGRAM COUNTERTOP GAS GRIDDLE THERMOSTATIC...
Страница 23: ...User Manual www AvantcoEquipment com 23 PARTS DIAGRAM COUNTERTOP GAS GRIDDLE MANUAL...
Страница 25: ...User Manual www AvantcoEquipment com 25 PARTS DIAGRAM COUNTERTOP RADIANT GAS CHARBROILER...
Страница 27: ...User Manual www AvantcoEquipment com 27 PARTS DIAGRAM COUNTERTOP GAS HOT PLATE...