32 (36)
7.2
Cleaning the attachment
Clean the attachment regularly to prevent accumulation of dirt which is more difficult to remove. A pressure
washer and mild detergent can be used for cleaning. Do not use strong solvents, and do not spray directly at
the hydraulic components, or at the labels on the attachment.
WARNING
Entanglement hazard - Risk of entanglement also persists during maintenance.
Always follow the safe stopping procedure before any cleaning, maintenance, or service
operation.
7.3
Inspection of metal structures
Also the metal structures of the attachment must be inspected regularly. Check visually for damages and
inspect the quick attach brackets and their surrounding area carefully. The attachment must not be used if it is
deformed, cracked, or torn.
Welding repairs are only allowed to be carried out by professional welders. When welding, only methods and
additives suited for steel used in attachment must be used. For more information about repairs contact your
nearest service point.
7.3.1
Lip plate
Replace the lip plate before the frame of the attachment becomes into contact with the ground. The lip plate
does not require adjusting.
7.4
Lubrication
There are a total of 3 lubricating points
on the attachment located at the
bearings of the belt.
Appropriate lubrication interval
depends heavily on use and operating
conditions. Lubricant must be added to
bearings at least after every 10 hours
of use. Adequate lubrication must be
ensured, and if the bearings are dirty,
lubricant must be added; added
lubricant will push out dirt.
Clean the end of the nipple before
greasing and add only a small amount
of grease at a time. All lubrication
nipples are standard R1/8" nipples.
Replace any damaged nipples.