AVALON Gourmet Révision A
Initial Setup
15
This equipment has a coffee brewing setpoint of 202 F* water temperature to offer a consistent beverage quality
to the users. There is a +/- 2 degree F tolerance.
.
3.8
Water Temperature
This is an average and is not what you would get from a manual temperature measure. The actual
water temperature fluctuates because cold water is added to the tank after every beverage delivery and
time is needed to heat the new incoming water up to setpoint.
You can also take the water’s brewing temperature manually by ordering a cup of hot water and
measuring its temperature with a thermometer. There may be a slight difference from the tank reading.
This is normal.
If you are experiencing large temperature differences, verify that your tank is clean and not obstructed
by mineral deposits and scale.
Unit safety measures
In the event of a temperature probe failure, the tank may start to boil. This will cause it to overflow into
the “Overflow Cup” and will automatically shut it off.
* Temperature can be set by user by accessing in the setup main menu.
Electronic
thermostat