Page 43
ZERO CLEARANCE (METAL) FIREPLACE - SPECIFICATIONS
LOCATION OF FLUE COLLAR DIMENSIONS REQUIRED FOR INSTALLATION INTO FIREPLACE AND
PANEL SIZING. WHEN INSTALLING THE 996 EXTENDED 45
o
FLUE, MAKE ALLOWANCE FOR THE
DISTANCE THAT THE 45
o
ELBOW WILL EXTEND PAST THE BACK OF THE INSERT.
TOP VIEW
996 Flush Top Flue
996 Extended 45
o
Flue
24
1/8"
4"
25 5/8"
19
3/8"
12 13/16"
15"
Firebox Front
24
1/8"
25 5/8"
19
3/8"
12 13/16"
3 5/8"
Firebox Front
10
3/8"
FIREPLACE SIZING
Measure and center the appliance into the fireplace based on the provided measurements.
A. Minimum Height
(Front)
B. Minimum Height
(Back)
C. Minimum Width
(Front)*
D. Minimum Width
(Back)*
E. Depth into Fireplace*
F. Extension onto Hearth
996
Flush
Top Flue
21 3/4"
21 3/4"
27 5/8"
27 5/8"
15"
5 3/8"
996
Extended
45
o
Flue
21"
21"
27 5/8"
27 5/8"
10 3/8"
10"
A
D
C
B
E
F
*
These dimensions include the 1" air space required between the sides and back of the insert and the
metal firebox of the zero clearance (metal) fireplace.