FREESTANDING INSTALLATION - SPECIFICATIONS
REQUIRED FLOOR PROTECTION:
Front = 16" NOTE: Front floor
protection is
measured from the
door opening.
Sides = 6"
Back =
6"
}
}
6 "
16" From Door Opening
6 "
CLEARANCE TO COMBUSTIBLES:
Backwall
Sidewall
A
B
E
D
Single Wall Connector
A. Sidewall to unit .........................
B. Backwall to unit.........................
C. Cornerwall to unit .....................
D. Connector to sidewall..............
E. Connector to backwall.............
F. Connector to cornerwall ..........
Reduced Clearance *
A. Sidewall to unit .........................
B. Backwall to unit.........................
C. Cornerwall to unit .....................
D. Connector to sidewall..............
E. Connector to backwall.............
F. Connector to cornerwall ..........
996
Flush
Top Flue
14"
14 1/2"
11"
23 1/2"
15 1/2"
19 1/2"
14"
9 1/2"
7 1/2"
23"
10"
15 1/2"
996
Extended
45
o
Flue
14"
17 1/2"
11"
23 1/2"
15 1/2"
16 1/2"
16"
14"
7 1/2"
25"
10"
12"
Cornerwall
C
F
Cornerwall
F
C
*
Components required for alcove, mobile home,
and reduced clearance installations are one of
the following listed double wall connectors and
chimney systems.
¥ DURAVENT model DVL with DURA-PLUS chimney
¥ AMERI-TEC model DCC with model HS chimney
¥ SECURITY model DP with SECURITY model ASHT or S2100
chimney
¥ METAL-FAB model DW with model TG chimney
¥ SELKIRK METALBESTOS model DS connector with model SSII
chimney
¥ OLIVER MACLEOD PROVENT model PV connector with model
3103 chimney
¥ GSW-JAKES EVENS SUPERPIPE 2100
¥
Standard Masonry Chimney with any one of the
above listed connectors