FREESTANDING INSTALLATION (Cont.)
Hearth Stove Installation Using a Horizontal Connection
(Continued)
Airtight
Insulated
Clean-Out
Min.
16"
Floor Protection
31 1/2" Min.
16 1/2" Min. With Shield
Flue Liner
with
Required
Airspace
Damper Closed
and Sealed with
Non-Combustible
Material
O R
Block-off Plate if
damper can not
be sealed
Minimum Clearance
from Chimney
Connector to
Unprotected Ceiling
18"
Listed or Approved
Thimble Assembly
Combustible
Wall
1" Clearance for
Completely
Exterior Chimney
or 2" Clearance for
Interior Chimney
and 2" Clearance
for N.F.P.A.
211-Type
Approved
Thimbles
Chimney
Connector
Min. 15 1/2" for
Single Wall, 10"
for Reduced
Clearance
Connector
996 Flush Top Flue
Shown Here Ð Follow the
clearances for the 996
Extended 45 Flue when
that model is used.
Combustible
Mantle
Follow the directions on the previous page for installation.