Counter Resetting
To reset the total counter value; send the following SMS message:
#CLA
The syntax of the command is the following:
#PWD123456#CLA
Output Settings
To activate the output relay, send a text command via SMS specifying the number of
seconds the output should stay on to the unit. It is possible to set up to maximum of 65,535
seconds.
#RLY
[N]
#
XXXXX
N stands for number
1
or
2
of Output
XXXXX stands for
5
digits value: The number of seconds
For example, assume you want to turn on the output relay number 2 for 1 hour, you should
send the following SMS message to the unit.
# PWD123456#RLY2=03600
To check the status of output relay
#PWD123456#RLY?
To activate the output relay to stay on, you can send the following commands by SMS
message to the unit.
#RLOP
[N]
=
X
N stands for number
1
or
2
of Output
X stands for ON (
1
) or OFF (
0
) value
To activate the output relay number 2 to stay on indefinitely, the syntax of the command is
the following:
#PWD123456#RLOP2=1
Setting the output relay
The output relays can be programmed to operate with a special feature. After being
programmed, it will activate both output relays to stay on. When the unit receives a call
from the user, it will turn off relay for a certain time period and turn on again. To program
this function, you can send the following commands by SMS message to the unit.
#FTRY=
F
F stands for function
0
–
2