8
Function
3
:
Functions as counter.
Activates the output relay 2 to stay on.
Sends an alert message once triggered.
Sends a counter alert message once the alarm counter reaches the alert value.
Function
4
:
Functions as counter.
Activates the output relay 2 for 1 second.
Sends a counter alert message once the alarm counter reaches the alert value.
Function
5
:
Sends an alert message once triggered.
For example, assume you want it to send an alert message each time the input is
triggered; you should send the following SMS message to the unit.
#PWD123456#CTC=5
Reading the total increment counter value
To read the total increment counter value, you can send the following SMS message to the
unit.
#COU?
The syntax of the command is the following:
#PWD123456#COU?
You will receive the total increment value from the unit by SMS.
Remote counter reading
To read the sub increment counter value, you can send the following SMS message to the
unit.
#COT?
The syntax of the command is the following:
#PWD123456#COT?
Wait to receive the sub increment value from the unit by SMS.
Note:
The sub increment counter value will be reset automatically each time the alarm
counter reached the alert value.