AV-GAD AVG064 Скачать руководство пользователя страница 2

 

AVG064 Description 

 
The AVG064 is a compact Dual Band GSM gate control. The unit is designed for cellular 
access control housed in an ABS case with a separated power supply. 
The  AVG064  contains  a  built-in  relay,  which  is  remote  controlled  and  is  applicable  for 
access control for parking lots, home automation, garage barriers, etc. 
The factory default is for European GSM band: 900/1800 MHz. 
AVG064  standard  pack  contains:  GSM  unit,  Zero  dB  GSM  antenna,  Installation  Manual, 
four  wires  Cable,  three  wires  cable  for  power  and  outputs.  Power  supply  is  not  included. 
For power supply the AV-20 wall plug type, or the AV-21 are compatible, both 12V 1A DC. 
 
The AVG064 support up to 64 accounts for gate or door opening, or use the “Open to all 
feature” (#ACM command). 
 
Programming and parameter settings are executed by SMS commands, PC connection is not 
available. 
 

AVG064 Wiring 

 
1.  Connections: 

Gently insert SIM card to 

SIM

 slot, located at the bottom side, as shown in figure 1. 

Connect GSM antenna to 

ANT

 connector.  

2.  Plug the Power Supply as shown in figure 1. 

 

 

 

Figure 1: AVG064 power and relay wiring 

 

SIM card parameters:

 Make sure the SIM you are using is SMS enabled, without a voice 

message service, without charge limits, caller ID is enabled, unlocked, PIN code disabled. 

 

Install the AVG064 GSM Remote Control Device in a place where there is GSM signal is well 
received  from  the  operator  you  want  to  use.  Check  it  with  a  phone  before  proceeding  with 
the installation. To install the device in a place with a weak signal, consider using an external 
antenna (option to be purchased separately with a 5m cable). 

Содержание AVG064

Страница 1: ...Gate Control AVG064 Integrated GSM module for Access Control Installation and Operation Manual Version 2 50 Edition I This product is subject to continual enhancement and therefore specifications may be changed or altered without prior notice www av gad com ...

Страница 2: ... door opening or use the Open to all feature ACM command Programming and parameter settings are executed by SMS commands PC connection is not available AVG064 Wiring 1 Connections Gently insert SIM card to SIM slot located at the bottom side as shown in figure 1 Connect GSM antenna to ANT connector 2 Plug the Power Supply as shown in figure 1 Figure 1 AVG064 power and relay wiring SIM card paramet...

Страница 3: ...ds pulse times modes are programmable at Gate Delay parameter Remove the PIN request from the SIM before inserting it in the unit otherwise the device will not work In order to do so insert the SIM in a phone and disable the PIN request usually there is a security menu that enables you to do so If you don t do it and switch on the unit more than 3 times you will have to reset the PIN using the PUK...

Страница 4: ...and we advise you to keep a list written somewhere to know which numbers are in and in which position To add a number the syntax of the command is the following PWD123456 WHL01 3593334444 Where 01 is the position in the list and 3593334444 is the number enabled Please note that it is possible to program up to a maximum of 10 digits for a number If it has more digits you should use the rightmost on...

Страница 5: ...0 5 seconds CSQ Check GSM signal quality This command is useful to see what GSM network signal level your AVG064 GSM Remote Control Device is receiving If you send the command PWD123456 CSQ You will receive an SMS with a signal quality ranging from 0 to 32 if it is 0 we doubt it will ever answer You should have a signal above 12 to ensure opening the gate in any condition Better if above 16 You sh...

Страница 6: ... RERN XXXXXXXX XXXXXXXX stands for 8 digits value ON 1 or OFF 0 for the 8 administrators For example if you assume only administrators 1 2 3 and 4 are to receive text alerts you would send the following SMS message to the unit PWD123456 RERN 11110000 Note You can only put 1 in the first 4 digits of the text command if there are only phone numbers stored in TEL1 TEL2 TEL3 and TEL4 The rest should b...

Страница 7: ...for 5 digits value The number of times For example assume you want it to send a counter alert message each time the input has been triggered for 5 times you would send the following SMS message to the unit PWD123456 COA 00005 Input behave setting This input can be programmed to behave differently it can count the input active high pulses generate an alarm message or activate relay To program the i...

Страница 8: ...ou should send the following SMS message to the unit PWD123456 CTC 5 Reading the total increment counter value To read the total increment counter value you can send the following SMS message to the unit COU The syntax of the command is the following PWD123456 COU You will receive the total increment value from the unit by SMS Remote counter reading To read the sub increment counter value you can ...

Страница 9: ...it PWD123456 RLY2 03600 To check the status of output relay PWD123456 RLY To activate the output relay to stay on you can send the following commands by SMS message to the unit RLOP N X N stands for number 1 or 2 of Output X stands for ON 1 or OFF 0 value To activate the output relay number 2 to stay on indefinitely the syntax of the command is the following PWD123456 RLOP2 1 Setting the output re...

Страница 10: ...an be programmed to operate at a programmable time To program this function you can send the following commands by SMS message to the unit SMW SS MM HH TTT G R SS is a 2 digits value stand for seconds MM is a 2 digits value stands for minutes HH is a 2 digits value stand for hours TTT is a 3 digits value stands for Turn Off time in seconds G stands for Group number 1 8 R stands for Relay number 1 ...

Страница 11: ...XXX stands for the 6 digits password PWD Default password is 123456 Common Problems Some phones cannot open the gate Verify that they send the caller ID when calling another phone Check that the number you see in the other phone is what you have programmed in the GSM Remote Control device I have inserted the SIM but the unit doesn t work Remove the PIN request from the SIM If you didn t do it and ...

Страница 12: ...rs installed not proper used improper abused altered damaged subjected to acts of God or on which the serial and data code altered or removed Av Gad will not be responsible for any dismantling or reinstallation expenses In order to exercise the warranty the purchaser must return the product delivery and transportation costs prepaid and insured to Av Gad After repair or replacement Av Gad assumes t...

Отзывы: