Mass Air Flow (Grams/Sec)
Range: 0 to 105 gr/sec
High Perf. Vehicles: 0 to 255 gr/sec
Mass air flow sensor input is used by the ECM to calculate fuel delivery.
As the air flow increases, the fuel delivery must also increase. Displayed
in grams per second.
Calculated Load Value
Range: 0% to 100%
An indication of the current airflow divided by peak airflow, where peak
airflow is corrected for altitude, if available. This value is not engine
specific. It gives the service technician an indication of the percent of
engine capacity being used (with a full load as 100%).
Commanded Secondary Air Status
Commanded Secondary Air provided to the exhaust system.
Engine Coolant Temperature
Range: -40 C to 215 C
The temperature of the vehicle coolant is used to determine when to
transition into closed loop and to calculate spark advance during cold
starts. The PCM converts the voltage from the sensor to a temperature.
Engine RPM
Engine Speed reading displayed in revolutions per minute.
Fuel Pressure (Gage)
Range: 0 to 765 kPaG
Fuel pressure of the fuel delivery system.
Fuel System Status
Information describing the operation of the fuel control.
Open loop - Operating condition during engine warm up/idle in which the
fuel mixture isn’t being corrected to compensate for a rich/lean condition.
Closed Loop - Operating condition in which the fuel mixture is being
corrected for a rich/lean condition.
OL Drive - Vehicle in Open Loop due to driving conditions (power
enrichment, deceleration).
OL Fault - Vehicle in Open Loop due to a detected system fault.
CL O2 Fault - Vehicle in Closed Loop, but a fault with at least one oxygen
sensor - may be using simple oxygen sensor for fuel control.
Ignition Timing Advance
Range: -64 to 63.5
The relationship between ignition timing and top dead center, displayed in
crankshaft degrees.
Page 57
OBD-II
G
ENERIC
O
PERATIONAL
D
ATA
I
TEMS
Содержание EX-SCAN 5000
Страница 1: ...USERS MANUAL...
Страница 95: ...NOTES Page 95...
Страница 96: ...NOTES Page 96...
Страница 97: ...NOTES Page 97...