 Specifications

(   ) is Max. pressure display range. 

 

For using mmH

2

O unit, multiply display value by 100.

Type

MPa  kPa 

kgf/cm² 

bar 

psi 

mmHg 

inHg 

mmH

2

Compound

pressure 

-

-100.0 to 100.0

(-101.3 to 110.0)

-1.020 to 1.020

(-1.033 to 1.122)

-1.000 to 1.000

(-1.013 to 1.100)

-14.50 to 14.50

(-14.70 to 15.95)

-750 to 750

(-760.0 to 825.1)

-29.5 to 29.5

(-29.91 to 32.48)

-102.0 to 102.0

(-103.3 to112.2)

-

-100 to 1000

(-101 to 1100)

-1.020 to 10.20

(-1.030 to 11.22)

-1.000 to 10.00

(-1.01 to 11.00)

-14.50 to 145.0

(-14.65 to 159.5)

-750 to 7500

(-757.6 to 8251)

-29.5 to 295

(-29.83 to 324.8)

-102.0 to 1020

(-103.0 to 1122)

 Pressure and Max. Pressure Display Range

Pressure type

Gauge pressure (In case of fluid type, standard pressure are sealed gauge pressure

1

)

Type

NPN or PNP open collector output type

NPN or PNP open collector

analog output or external input type

Model

PSQ-  C01  - 

PSQ-  C1  - 

PSQ-  C01  U- 

PSQ-  C1  U- 

Rated pressure range -100.0 to 100.0kPa

-100 to 1,000kPa

-100.0 to 100.0kPa

-100 to 1,000kPa

Display&Setting

pressure range

-101.3 to 110.0kPa

-101 to 1,100kPa

-101.3 to 110.0kPa

-101 to 1,100kPa

Min. display unit

0.1kPa

1kPa

0.1kPa

1kPa

Max. 

pressure 

range

Pneumatic type 2 times of rated pressure

1.5 times of rated pressure 2 times of rated pressure

1.5 times of rated pressure

Fluid type

3 times of rated pressure

Applied fluid

• Pneumatic type: 

air, non-corrosive gas

• Fluid type: 

air, non-corrosive gas and fluid that do not corrode stainless steel 316L

Power supply

12-24VDC

 (ripple P-P: max. 10%) 

Allowable voltage range 90 to 110% of rated voltage

Current consumption

Max. 50mA

Max. 50mA (analog output: max. 70mA)

Control output

NPN or PNP open collector output

 Load voltage: max. 30VDC

         Load current: max. 100mA         Residual voltage: max. 2VDC

Hysteresis

2

Min. display interval

Repeat error

±0.2% F.S. ± min. display interval

Response time

Select one; 2.5ms, 5ms, 10ms, 25ms, 50ms, 100ms, 250ms, 500ms, 1,000ms, 5,000ms 

Protection circuit Output short over current protection circuit

Analog

output

3

Voltage 

output

-

 Output voltage: 1-5VDC

 ±2.5% F.S.   

 Linear: max. ±1% F.S.

 Resolution: 1/2,000   

 Output impedance: approx. 240Ω

 Response time: 50ms

Current

output

-

 Output current: DC4-20mA ±2.5% F.S.   

 Linear: max. ±1% F.S.

 Resolution: 1/2,000   

 Output impedance: approx. 100kΩ

 Response time: 50ms

External input

3

(Auto shift/

Remote zero/Hold)

-

 ON voltage: max. 0.4VDC

   

 OFF voltage: 5-Vin or open 

 Resolution: 1/2,000   

 Output impedance: approx. 100kΩ 

Display digits

Present value (PV) display part, setting value (SV) display part: 4-digit

Display method

12-segment LCD method

Min.

display

interval

MPa

0.001

0.001

0.001

0.001

kPa

0.1

1

0.1

1

kgf/cm

2

0.001

0.01

0.001

0.01

bar

0.001

0.01

0.001

0.01

psi

0.02

0.2

0.02

0.2

mmHg

1

-

1

-

inHg

0.1

-

0.1

-

mmH

2

O

0.1

-

0.1

-

Display accuracy

0 to 50

: max. ±0.5% F.S., -10 to 0

: max. ±1% F.S.

Insulation resistance

Over 50MΩ (at 500VDC megger) 

Dielectric strength

1,000VAC 50/60Hz for 1min 

Vibration

1.5mm amplitude at frequency of 10 to 55Hz (for 1min) in each X, Y, Z direction for 2 hours

Environ

-

ment

Ambient temp.  -10 to 50

, storage: -20 to 60

Ambient humi. 30 to 80%RH, storage: 30 to 80%RH

Cable (fluid type)

Ø4mm, 5-wire, 3m (AWG24, core diameter: 0.08mm, number of cores: 40, insulator out diameter: Ø1mm)

Protection structure

• Pneumatic type: 

IP40 (IEC standard)                   

• Fluid type: 

IP65 (IEC standard)

Material

• Pneumatic type - 

Front case: polycarbonate, rear case: polycarbonate, pressure port: brass-nickel plated

• Fluid type - 

Front case: polycarbonate, rear case: polyamide 6, pressure port: stainless steel 316L

Approval

Weight

4

• Pneumatic type: 

approx. 165g (approx. 80g)       

• Fluid type: 

approx. 210g (approx. 125g)

1: The unit is sealed structure. It is based on atmospheric pressure 101.3kPa.

2: In hysteresis output mode, it is variable.

3: Select one between analog output (voltage or current) and external input. 

4: The weight includes packaging. The weight in parenthesis is for unit only. 

 

For using mmH

2

O unit, multiply display value by 100.       

Environment resistance is rated at no freezing or condensation.

Содержание PSQ Series

Страница 1: ...60 0 133322kPa 101 32472kPa Features Pressure Conversion Chart to from Pa kPa MPa kgf cm2 mmHg mmH2O psi bar inHg 1Pa 1 0 001 0 000001 0 000010197 0 007501 0 101972 0 000145038 0 00001 0 0002953 1kPa 1000 000 1 0 001 0 010197 7 500617 101 971626 0 145038 0 01 0 2953 1MPa 1000000 1000 1 10 197162 7500 61683 101971 626 145 038243 10 295 299875 1kgf cm2 98066 5 98 0665 0 098067 1 735 55924 10000 0005...

Страница 2: ...0ms 500ms 1 000ms 5 000ms Protection circuit Output short over current protection circuit Analog output 3 Voltage output Output voltage 1 5VDCᜡ 2 5 F S Linear max 1 F S Resolution 1 2 000 Output impedance approx 240Ω Response time 50ms Current output Output current DC4 20mA 2 5 F S Linear max 1 F S Resolution 1 2 000 Output impedance approx 100kΩ Response time 50ms External input 3 Auto shift Remo...

Страница 3: ...y for over 4 sec to enter parameter 2 group Setting mode Press the M key to select the setting items Press the M key for over 2 sec to return RUN mode 5 key RUN mode Press the key to set preset value of output operation mode Press the M keys to set key lock unlock Press the keys to adjust zero point Press the M keys to set peak hold Preset value setting mode Press the key to increase decrease sett...

Страница 4: ...ss 0 5 to 7mm 31 0 0 4 When N units are installed in series 31 0 0 4 31 N 3 5 N 1 Min 55 Integrated installation set Pneumatic Fluid type Separate installation set Pneumatic type 28 2 40 30 40 42 35 26 3 20 25 8 Rear panel bracket Front panel bracket Front cover PSO P01 Front cover PSO P02 Panel cut out Front Rear pael bracket set PSO B04 Panel bracket PSO B02 Panel cut out 6 75 7 37 41 34 2 42 39...

Страница 5: ...own V blue 0V black OUT1 white OUT2 12 24VDC orange analog output external input Load Load RUN mode Preset value setting Zero point adjustment Parameter 2 group Key lock High Low peak hold for over 1 sec It sets reference pressure to the current atmospheric pressure as zero for over 1 sec for over 1 sec Output short over current protection circuit Output short over current protection circuit Outpu...

Страница 6: ...ld The function to hold present value PV and control output while signal is input When OUT1 operation mode is set as fOUT or applied pressure is higher lower than the display pressure range auto shift SHFT remote zero ZERO functions are not available A V ShOT 1 Auto shift applied terminal OUT1 OUT2 ALL OUT1 OUT2 OUT1 OUT2 Select auto shift applied terminal Appears when Analog output External input...

Страница 7: ... Only checking parameters 0000 sOUT Control output switching NPN PNP NPN PNP Select type of control output NPN HYS Hysteresis for easy mode 1 to 1 1 1 1 1 1 1 1 Bar type Min 1ea Max 8ea Set the hysteresis for easy mode Rated pressure range Hysteresis per 1 Bar 100 0 to 100 0kPa 0 1kPa 100 0 to 1 000kPa 1kPa Appears when OUT1 or OUT2 operation mode is easy mode Although the display unit is changed ...

Страница 8: ...setting by output operation mode Output operation mode Preset Setting range Factory default 100 0 to 100 0kPa 100 to 1 000kPa EASY Easy P Pressure detection level Min display pressure P Max display pressure 05 0 0500 HYsM Hysteresis ST Pressure detection level Min display pressure ST Max display pressure 05 0 0500 HYS Hysteresis level Min display pressure HYS ST 5 0 0000 WIN Window com parison LO ...

Страница 9: ...tput voltage or current and external input auto shift remote zero hold are not available at the same time Analog output A V Analog voltage output A C Analog current output External input SHFT Auto shift ZERO Remote zero HOLD Hold Preset setting by external input mode External input mode Preset Setting range Factory default SHFT Auto shift ShIN Auto shift correction value Min preset setting value S...

Страница 10: ...1 ST2 Hysteresis is fixed as Min display interval The pressure detection level SET is shown in the below formula ST1 ST2 2 SET Pressure 1 Min display interval 1 1 1 ST1 ST2 SET SET ST1 ST2 OUT1 N O OUT2 N O OUT1 N C OUT2 N C ST2 SET ST1 ON OFF ON OFF ON OFF ON OFF Time Time Time Time Time Forced output control mode fOUT RUN mode fOUT Regardless of setting value it maintains comparison output OFF a...

Страница 11: ...COPY Slave unit PV display arbitrary value SV display OK M Master Slave brown V blue 0V black OUT1 black OUT1 white OUT2 white OUT2 Auto Shift Remote Zero Hold input Output mode change OUT1 operation mode There are 4 kinds of control output mode in order to realize the various pressure detection Hysteresis mode HYsM When needed to change hysteresis for detecting pressure Window comparison output m...

Страница 12: ...the SV display part in RUN mode There are 3 types displaying SV STD displaying unit UNIT none OFF RESET This function is to reset all parameters as factory default except control output SV to prevent wrong settings or difficult operation Password This function is to limit parameter settings to check the parameter or to change the parameter settings only for entering the set password 0000 Password ...

Страница 13: ...t this unit must avoid direct touch with water oil thinner etc 5 PSQ Series has panel bracket PSO B02 front cover PSO P01 are sold separately When mounting the unit on panel please follow the below figure The tightening torque of one touch fitting should be max 10N m It may cause mechanical problems Front cover PSO P01 Mounting panel panel thickness 0 8 3 5mm Panel bracket PSO B02 Body PSQ SMPS F ...

Отзывы: