2 Communication Setting
20
© Copyright Reserved Autonics Co., Ltd.
10th
Below P2P channel, double-click ‘P2P block’ and set as below.
CH P2P
function
Conditional
flag
Command
type
Data type
Destination station
number
2
READ(PV)
M00000 to
M00003
2.
Continuous
WORD
(size: 2)
Enter destination station
(1 to 4)
* Refer to the below table for variable setting for PV and SV.
Click ‘Setting’ to set variable.
* Modbus Mapping Table
Address
Type
Setting range
Factory default
301002(03E9)
PV
Present
value
-19999 to 99999
301003(03EA)
* Be sure that
MP Series requires 2 addresses; 03E9, 03EA for reading present value.