Autometers Systems IC7-C Скачать руководство пользователя страница 6

6

RESET MAXIMUM DEMAND

Function 12.

To reset maximum demand enter 
Function 12 
(page 5 function operation 
display)
press “enter” key. 
Press “Funct” key to return to 
normal display.  

SETTING CURRENT 
TRANSFORMER RATIO.

Function 13.

To set C.T. ratio see page 3.

DISPLAY CONTRAST.

Function 16.

To alter the display  enter function 
16.
(See Page 5 function operation 
display)
The curser will flash on one of the 
two signs.
To increase contrast press “enter” 
key to move the curser to the 
flashing “+” sign, 
Display will change, press the 
“Enter “key to step the contrast. 
Press “Funct” key to return to 
normal display.

CURRENT TRANSFORMER 
AND VOLTAGE CONNECTION 
SETTINGS

Function 50

To check connections enter 
function 50.
(See Page 5 function operation 
display)
Press “Funct” key to see 
connections.
Press “Funct” key to return to 
normal display.  

PULSE TEST

Function 60

To test the relay output enter 
function 60
(See Page 5 function operation 
display)
Press “enter key”
Press “Funct” key to return to 
normal display. 

PRESS ENTER KEY

TO R ESET MD

RAT I O

CT PR I MARY=**** / 5
NT PR I MARY=**** / 5

D I SPLAY CONTRAST

+

-

CONNECT I ON

L 1 i mpo r t

V 1 OFF

L2 i mpo r t

V2 OFF

L3 i mpo r t

V3 OFF

RELAY PULSE TEST

PULSE EVERY SECOND

PRESS ENTER TO EX I T

Diagram 6.

L3

N

LOAD

MAINS

L3

L2

L2

L1

L2

S2

S1

P2

P1

S2

S1

P2

P1

S2

S1

P2

P1

S2

S1

P2

P1

L1

1 Amp

230/400Volt 50Hz
0.1-5Amp

Communication

Sockets

Cable Channel

Cable Channel

Fu

se

Cable Entry

DILL SWITCH

Position of Communication Sockets

ON

DIP

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

ON

DIP

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

space:nowrap" class="ft013">4

5

6

7

8

1

2

3

4

5

6

7

8

Содержание IC7-C

Страница 1: ...installation and operation manual IC7 C and IC9 C horizon r a n g e The fusion of land based metering and ether based monitoring 9...

Страница 2: ...ing Slide the back of the meter first through the opening on the rear side of the door and then push the bezel from the front side over the protruding clear plastic and push fully home until it locks...

Страница 3: ...t programming details for your chosen CT ratios e When the process is complete press the Function key to take you back to the default screen Note When setting CT ratios and if you have only three digi...

Страница 4: ...IMPORT ENERGY KWH 000000 00 KVAH 000000 00 KVARH 000000 00 EXPORT ENERGY KWH 000000 00 KVARH 000000 00 VOLTAGE L 1 000 0 L 1 L2 000 0 L2 000 0 L2 L3 000 0 L3 000 0 L3 L1 000 0 FREQUENCY 50 00Hz AMPS L...

Страница 5: ...will take you to the desired screen To return to the normal screen press FUNCTION key again If you enter an incorrect number or a function which is not available on this model you will see the screen...

Страница 6: ...50 To check connections enter function 50 See Page 5 function operation display Press Funct key to see connections Press Funct key to return to normal display PULSE TEST Function 60 To test the relay...

Страница 7: ...ches needs to be in the on position To allocate meter register number 14 dill switches numbers 5 6 and 7 must be in the on position To allocate meter register number 39 dill switches numbers 3 6 7 and...

Страница 8: ...se Duration 80 100 ms closure Pulse Value C T Value less than 1000 5A 1 kWh imp C T Value 1000 5A or more than 10 kWh imp 0 4 0 3 0 2 0 1 0 1 0 2 0 3 0 4 0 1 1 0 2 0 3 0 4 0 5 0 6 0 IC9 Load Curve 0 5...

Страница 9: ...n depth stock holding combine to provide a level of service which has earned the appreciation of customers across the spectrum of the UK and export markets Computerised distribution systems are geared...

Отзывы: