DPM2-E Electrical User Manual, 1st Edition

User Manual - DPM2-E Series Electrical Panel Meters

24

Technical Specifications Continued

Conversion

Technique

Sigma-Delta

Resolution

±16 bits

Conversion rate

20

 times per second

Display

Range

-9999 to +9999, 4 Red LED digits 14mm, selectable decimal point position

LEDs

Relay 1, Relay 2 status

Display refresh rate

50ms

Display / Input overrange 

indication 

"

-OuE

” , “

OuE

Relays 

(DPM2-E-2RL-HL only)

(2) Relays, Form C 

SPDT

Nominal contact rating..............................................8A at 250VAC / 24VDC
Maximum switching current (resistive load)............8A
Maximum switching power.......................................2000VA / 192W
Maximum switching voltage.....................................400VAC / 125VDC

Contact resistance.....................................................≤100mΩ at 6VDC @ 1A

Contact type..............................................................SPDT

Operate time..............................................................≤10ms

Power Supply and 

Fuses

20-265VAC 50/60 Hz or 11-265VDC (Recommended fusing 3A/250V, DIN 41661)

Power Consumption

3W

Filter

Cutoff frequency (-3dB) 

7.3Hz to 0.2Hz

Slope

-20dB/Dec.

Environmental 

Conditions

Operating temperature

-10ºC to +60ºC (14ºF to 140ºF)

Storage temperature

-25ºC to +85ºC (-13ºF to 185ºF)

Relative humidity  

(non-condensing)

<95% @ 40

ºC (104

ºF)

Maximum altitude

2000m

Frontal protection 

degree

IP65

Environmental Air

No corrosive gases permitted

Agency Approval

CE

Содержание ProSense DPM2-E Series

Страница 1: ...ProSense DPM2 E Series Digital Panel Meter for ac or dc voltage and amperage electrical input signals Models DPM2 E HL DPM2 E 2R HL User Manual...

Страница 2: ...nals 7 Wiring Examples 9 1A DC and 0 1A AC Input Ranges Wiring 9 5A DC and 0 5A AC Input Ranges Wiring 9 60mV DC 100mV DC and 0 60mV AC 0 100mV AC Shunt Input Ranges Wiring 10 20V DC and 0 20V AC Inpu...

Страница 3: ...l User Manual 1st Edition User Manual DPM2 E Series Electrical Panel Meters 3 Configuration Lock Out Continued 21 Configuration Lock Out Continued 22 Technical Specifications 23 Instrumentation Config...

Страница 4: ...legislation regarding waste of electrical and electronic equipment from products put on the market after August 13 2005 the user can give it back without any cost to the place where it was acquired to...

Страница 5: ...about our products and our company www AutomationDirect com Agency Approvals Description The ProSense DPM2 E series offers a simple low cost digital display of AC or DC voltage or amperage electrical...

Страница 6: ...AC DC current input 1A 5A shunt 60mV shunt 100mV AC or DC powered Optional 2 Form C SPDT relays N O or N C operation Activation on increasing or decreasing input signal Hysteresis or time delay opera...

Страница 7: ...from the panel pull the rear fixing clips latching tabs outwards until they are disengaged then slide the fixing clips back over the case Wiring Terminals CN3 1 2 CN2 1 2 3 4 5 6 7 CN1 CN4 1 2 3 4 5...

Страница 8: ...te to signal terminals CN2 and power terminals CN1 2500Vrms for 1 minute to signal terminals CN2 and relays terminals CN3 or CN4 2500Vrms for 1 minute to power terminals CN1 and relays terminals CN3 o...

Страница 9: ...gauge and length should be used to prevent the total resistance of the measuring circuit R1 R2 Ri from exceeding the Burden rating of current transformer 5A DC and 0 5A AC Input Ranges Wiring DC AC D...

Страница 10: ...the shunt and the DPM meter 20V DC and 0 20V AC Input Ranges Wiring N L DPM2 E 1 5 V 20V DC AC MAX DC AC 20V RANGE CONNECTION 200V DC 600V DC and 0 200V AC 0 600V AC Input Ranges Wiring DC AC 200V RAN...

Страница 11: ...Illuminates for negative readings Illuminates for negative values 3 Key Pad 4 Setpoint 1 LED Illuminates when setpoint 1 turns active Illuminates when setpoint 1 turns active 5 UP key No application S...

Страница 12: ...ntire configuration In this visualization mode the meter automatically switches back to RUN mode after 15 seconds since last key press MAIN MENU ENTER Vertical displacement Validates data UP Increases...

Страница 13: ...C 20 Available range options for DC and AC input voltage are identical Signal Ranges V DC 600V 200V or 20V V AC 0 600V 0 200V or 0 20V DC and AC Current AdC 5A 1A AAC 60 100 Available range options fo...

Страница 14: ...the meter at the CN2 input connector and operational Display values are configured manually through the three keys as in the previous case This method is suitable when signal values at each point are...

Страница 15: ...st DISP 1 In an increasing mode display value increases proportionally to the input value whereas in a decreasing mode display value decreases Direct acting increasing proportional mode Reverse acting...

Страница 16: ...e indication 0000 Value entered in counts within display range DECIMAL POINT 00 00 Setting of decimal point position Decimal point can be located in any position and will be the same for Display 1 and...

Страница 17: ...to be configured are the following SETPOINT VALUE 00 00 Value entered in counts within display range The decimal point position is previously defined in display configuration menu ACTIVATING MODE Hi H...

Страница 18: ...ecreasing Asymmetrical Hysteresis Both relay output actions can be controlled by a hysteresis level which is configurable in counts within full available display Decimal point position is the previous...

Страница 19: ...minimum value and finally a third pressing shows run before returning to RUN mode RESET function is activated while visualizing maximum or minimum values and the SHIFT key is pressed for at least 3 s...

Страница 20: ...ation lock out is available By default the unit is delivered unlocked giving access to all programming levels Once in this menu the first option will be to choose between lock out level setting LiSt o...

Страница 21: ...ng main menu initial indication will be dAtA instead of Pro On the other hand when no option is selected routine moves on to next step to configure a selective lock out When a selective lock out is se...

Страница 22: ...to visualize maximum or minimum values by pressing SHIFT key although instrument internally continues detecting and saving new extreme values reached by input signal Once the instrument programming is...

Страница 23: ...V EMI max Influence 20V 10mV 200V 100mV 600V 300mV 0 to 20V 20mV 0 to 200V 200mV 0 to 600V 600mV 1A 500 A 5A 2 5mA Shunt 60mV 30 V Shunt 100mV 50 V 0 to 1A 1mA 0 to 5A 5mA Shunt 60mV 60 V Shunt 100mV...

Страница 24: ...8A at 250VAC 24VDC Maximum switching current resistive load 8A Maximum switching power 2000VA 192W Maximum switching voltage 400VAC 125VDC Contact resistance 100m at 6VDC 1A Contact type SPDT Operate...

Страница 25: ...DPM2 E Series Electrical Panel Meters 25 Instrumentation Configuration Notes INPUT TYPE RANGE DISPLAY CONFIG MODE INPUT 1 DISPLAY 1 INPUT 2 DISPLAY 2 FILTER 0 9 SETPOINTS SET1 MODE DLY HYS SET2 MODE D...

Отзывы: