background image

 

Owner Installation Instructions 

NeoSlider™ - Sliding Gate Opener NES-24V1

23

Viewing And Editing Parameters 

This section illustrates how to locate, view and adjust 
parameters. 

Locating parameters 

Refer to MENU STRUCTURE on Page 14 or the preceding 
section for CONTROL BOARD ADJUSTMENTS. Locate 
the required parameter and note the MENU number. The 
example used in 

(Fig. 17)

 displays “CLOSE LOCK TIME”

Changing setting 

1. Press NEXT/PREV to navigate to the required menu. 
2. Press SET to show sub-menu. 
3. Press NEXT/PREV to go to required sub-menu. 
4. Press SET to enter edit mode. 
5. Press UP/DOWN to change parameter setting. 

Holding the button down causes the parameter’s 
value to change rapidly. The longer the button is held, 
the faster the value changes. 

6. Press SET to SAVE setting. 

Reload default setting 

1. Press NEXT/PREV buttons to display LOAD DEFAULT 

screen. 

2. Press SET to load the default value. 

Return to menu 

If the parameter’s value is not to be changed, press 
EXIT to return to sub menu. Press EXIT again to return 
to the MAIN SCREEN.

17

fi g

#LOSE,OCK
4IME3%#

18

fi g

#LOSE,OCK
4IME3%#

Parameter name

Parameter 
value

Displays next 
parameter 
in list

Parameter number in list

Enter Edit 
Mode

Displays previous 
parameter in list

Returns back to menu

Enter Edit Mode

View Mode (No cursor)

Edit Mode (Cursor shown)

Increase 
value

Displays “Load 
Default?” screen, 
giving option of 
loading default value

Exits back to View Mode 
with no changes made

Decrease 
value

Saves new 
value and exits 
back to View 
Mode

Displays “Load 
Default?” screen, 
giving option of 
loading default 
value

Cursor shown

Содержание NES-24V1 NeoSlider

Страница 1: ...NES 24V1 NeoSlider INSTALLATION INSTRUCTIONS OWNERS COPY Sliding Gate Opener Featuring TrioCode Technology Ne Slider Part 13311 Manual v1 00...

Страница 2: ...the extent that such may be lawfully excluded hereby expressly disclaims all conditions or warranties statutory or otherwise which may be implied by laws as conditions or warranties of purchase of an...

Страница 3: ...Menu 4 Lock times 21 Menu 5 Light times 21 Menu 6 Motor settings 21 Menu 7 Operating modes 22 Viewing and Editing Parameters 23 Coding Transmitter 24 Transmitter Editing 25 Transmitter Management 27 C...

Страница 4: ...perty damage can result from failure to follow this warning Make sure that the Safety Obstruction Force system is working correctly and is tested every month Test as per the Installation Instructions...

Страница 5: ...ls Extreme caution is recommended when using Auto Close mode All safety instructions above must be followed In order for the gate opener to sense an object obstructing the gateway some force must be e...

Страница 6: ...and makes code grabbing a thing of the past These transmitters also overcome interference issues by simultaneously sending a signal over three different frequencies Even if two of the three signals a...

Страница 7: ...dicated outputs for operating an electric lock and warning or courtesy lights The timing of these outputs can be adjusted to suit your needs In addition a button on a remote transmitter can be coded t...

Страница 8: ...on The Automatic Technology NeoSlider sliding gate opener is designed to operate most residential sliding gates The gates must be in good working condition and should operate freely by hand Initial Ch...

Страница 9: ...a line parallel to the face of the gate for the mounting holes The distance from the gate is determined by the formula 38mm Rack Width Therefore if using an Automatic Technology rack the distance is 7...

Страница 10: ...entres of the rack s mounting slots The rst section of rack should start 20mm from the edge of the gate 3 Drill and tap for 6mm screws 4 Once the rst section of the rack is mounted check that it meshe...

Страница 11: ...ove it 5 to 10mm towards the centre of the gate Align the face of the limit actuator with the side of the rack and screw the limit actuator to the rack Fig 06 4 Re check limit positions by manually op...

Страница 12: ...C N O input terminal SWP N O input terminal PED N O input terminal Engage sensor microswith input Console Previous button Console Up Open button Console Next button Console Exit button Console Down Cl...

Страница 13: ...r NES 24V1 13 Control Board Layout ENGAGED POSITION PROGRAMMER 0V ANT 24VAC SBY 3 24VDC OUT LIGHT RELAY LOCK RELAY V IN V P E BEAM COM OPN STP CLS OSC SWP PED MOTOR FUSE DCB02 2XX 01 03 02 04 05 06 07...

Страница 14: ...lay See page 30 Transmitter testing See page 30 Event history display See page 30 Periodic service cycle counter See page 31 Cycle and event counter See page 31 Memory usage See page 30 Parameter list...

Страница 15: ...24V1 15 Initial Electrical Installation CAUTION Cables which have a green yellow coloured insulation are for earthing purposes only Never use these cables for any other purpose Warning A quali ed elec...

Страница 16: ...el limits for a single gate Powering Up The Drive Unit 08 g 09 g This section shows how to set the travel limits The procedure can be partly completed using a transmitter In order to use a transmitter...

Страница 17: ...the open direction Automatic limit adjustment and load pro le After a brief pause the controller will automatically close and open the gate several times This adjusts the speed at which the limits are...

Страница 18: ...e Fig 16 Setting Pedestrian Position MENU 10 3 Set Pedestrian PR E S S 14 g 16 g Ped n Opening Time 5 PR E S S PR E S S 0 E D N C C E S S 0 R E S S T O C C E S S 53 15 g Recalculate Force Margins Repr...

Страница 19: ...rigger will move the gate in the opposite direction to the last travelled Pedestrian access PED function Activated by PED terminal with N O switch or by transmitter button with PED function assigned T...

Страница 20: ...selected by entering a non zero time for the Ped n A C parameter When selected the gate will auto close after being opened for pedestrian access unless it was following a reverse from an obstruction P...

Страница 21: ...Min Max Default Step Unit Menu No ON AFTER CYCLE LIGHT TIME Time light remains on for after a cycle 0 255 60 1 Sec 5 ON BEFORE OPEN CYCLE LIGHT TIME Minimum time light is activated for prior to openi...

Страница 22: ...facilities so that the control board can be shut down without having to disconnect the battery backup system Password protection The password feature enables all parameters and con guration settings...

Страница 23: ...The longer the button is held the faster the value changes 6 Press SET to SAVE setting Reload default setting 1 Press NEXT PREV buttons to display LOAD DEFAULT screen 2 Press SET to load the default...

Страница 24: ...transmitter codes from the receivers memory will allow you to choose either TrioCode or Tri Tran transmitters again Coding transmitter button Step 1 Navigating to code transmitter menu 1 Press NEXT t...

Страница 25: ...and bottom lines to select the desired eld 2 Press UP or DOWN to change the displayed value Fig 25 The available functions are shown below Selecting OFF will prevent the opener responding to that but...

Страница 26: ...rial Number display 1 Press NEXT PREV to move cursor over ID eld 2 Press NEXT to reveal Serial Number Fig 27 The serial number display is provided for additional means of identi cation The transmitter...

Страница 27: ...ransmitter edit procedure 3 Press NEXT to enter transmitter list and edit mode Fig 32 The display will change as shown in Fig 33 This method is used if the transmitter is not available Method 2 Use tr...

Страница 28: ...SMITTER PROCEDURE will be initiated and the new transmitter will replace the existing one Note that the button functions and name of the existing transmitter will be transferred to the new transmitter...

Страница 29: ...OPN wait for the gate to complete the cycle 3 Activate remote code set mode Using a small pin press and hold through the Coding Hole of the existing transmitter for two seconds Fig 44 4 Code new trans...

Страница 30: ...ial numbers are to be displayed The opener will then beep each time a transmission is received If the transmitter button is stored in the controller memory and has a function assigned to it a second s...

Страница 31: ...AMETER VIEWING AND EDITING The service counter is set at 60 000 from the factory Menu 8 6 Counters The opener keeps a count of number of times a particular event occurs The list of event counters kept...

Страница 32: ...ed to view the Memory Tool options To execute the displayed option simply press SET Menu 9 1 Clr control This option will clear the gate control memory and reload the factory set defaults for paramete...

Страница 33: ...PE 2000TS receiver Make sure to align the beams correctly Follow the manual supplied with the PE Beams Alignment Power up the PE Beams The green LED on the transmitter and red LED on the receiver shou...

Страница 34: ...ill not open fully Gate limits position need to be reset Reset limits positions See Page 16 17 Opener beeping and gate does not move Disengagement lever opening Disengage connector not plugged in Clos...

Страница 35: ...No of code combinations Over 4 29 billion random codes Code generation Non linear encryption algorithm Transmitter battery CR2032 NOTE 1 The maximum gate size that the NeoSlider can be installed on i...

Страница 36: ...key 64620 26 Top and bottom lock cap 15220 27 Microswitch ABS 111454 69261 28 M SW harness ESV24 240 12240 29 Hinge pin 62560 30 Rod disengagement 62565 31 Antenna 433MHz L 1 95m coax cable 61972 32...

Страница 37: ...Owner Installation Instructions NeoSlider Sliding Gate Opener NES 24V1 37...

Страница 38: ...igence or failure to maintain the equipment in a proper working order as per clauses d through i k installation adjustment or use which is not in accordance with the instructions set out in installati...

Страница 39: ...Owner Installation Instructions NeoSlider Sliding Gate Opener NES 24V1 39 Purchased from Phone Installed by Date Serial No Notes And Record...

Страница 40: ...trademark of B D Doors and openers No part of this document may be reproduced without prior permission In an ongoing commitment to product quality we reserve the right to change speci cation without...

Отзывы: