background image

2

Owner Installation Instructions 

NeoSlider

TM

 - Sliding Gate Opener NES-500 / NES-800

Automatic Technology Australia Pty Ltd to the extent that such may be lawfully excluded hereby expressly disclaims all conditions or warranties, statutory 

or otherwise which may be implied by laws as conditions or warranties of purchase of an Automatic Technology Australia Pty Ltd Garage Door Opener. 

Automatic Technology Australia Pty Ltd hereby further expressly excludes all or any liability for any injury, damage, cost, expense or claim whatsoever 

suffered by any person as a result whether directly or indirectly from failure to install the Automatic Technology Australia Pty Ltd Garage Door Opener in 

accordance with these installation instructions. 

NeoSlider

TM

Sliding Gate Opener NES-500 / NES-800

Contents
1. Important Safety Instructions 

3

2. Control Board Layout 

4

3. Set Up Requirements 

5

3.1 Kit Contents 

5

3.2 Choosing your Set up  

5

3.3 Initial Checking  

5

4. Drive Unit Installation 

6

4.1 Mounting the Drive Unit 

6

4.2 Installing antenna 

6

5

Rack & Limit Actuator Installation 

7

5.1 Mounting rack to gate 

7

5.2 Fixing limit actuator to rack 

7

6. Programming The NeoSlider

TM 8

6.1 Common Programs 

8

6.2 Powering up the NeoSlider

TM

 

8

7. Safety Beams 

8

7.1 Installation of Safety Beams to the NeoSlider

TM

 

8

7.2 Safety Beam Failure Emergency Close (SBFEC) 

8

8. Setting Limits 

9

8.1 Setting Travel Limits 

9

8.2 Setting the left/right installation side settings  

9

8.3 Setting close travel limit   

9

8.4 Setting open travel limit 

9

8.5 Automatic limit adjustment and load profile  

9

8.6 Pedestrian access position  

9

8.7 Errors during setting of travel limit  

9

8.8 Recalculate Force Margins 

9

9. Safety Obstruction Force Test 

10

9.1 Testing Close Cycle  

10

9.2 Testing Open Cycle  

10

9.3 Force Pressure For Close and Open Cycle. 

10

9.4 Reprofiling Travel 

10

10. Coding Transmitter 

11

10.1 Coding Transmitter Button  

11

10.2 Selecting Function Of The Button  

11

10.3 Returning To Main Screen  

11

10.4 Selecting The Function To Be Coded  

11

11. Emergency Release 

12

11.1 Your gate CAN NOT be used by the opener when:  12
11.2 Your gate CAN be used when: 

12

11.3 To Disengage the Opener: 

12

11.4 To Re-Engage the Opener: 

12

12. Setting Pedestrian Position 

12

12.1 Setting pedestrian position 

12

12.2 Pedestrian Position Set  

12

12.3 Error Displays 

12

13. Auto-Close Mode 

13

13.1 Setting Up Standard Auto-Close 

13

13.2 Safety Beam Triggered Auto Close 

13

13.3 Pedestrian Auto-Close 

13

13.4 Auto-Close After Obstruction  

13

14. Accessories Installation  

14

14.1 Fitting Solenoid Or Magnetic Locks  

14

14.2 Fitting Courtesy Lights  

14

15. Battery Replacement 

15

16. Battery Disposal 

15

17. Specifications 

16

18. Troubleshooting 

17

19. Appendix  

18

A - Console Menu Structure 

18

B - Viewing & Editing Parameters 

20

C - Wiring Dual NeoSlider Kit 

21

D - Control Board Adjustments 

22

E- Diagnostic Tools 

23

F - Memory Tools 

24

G- Transmitter Editing 

25

H- Transmitter Managment 

26

20. Warranty and Exclusion of Liability 

27

Содержание NeoSlider TrioCode 128 NES-500

Страница 1: ...NeoSliderTM NES 500 NES 800 Sliding Gate Openers Ne Slider Doc 160065_05 Part 13448 Released 14 12 17 ...

Страница 2: ...ravel Limits 9 8 2 Setting the left right installation side settings 9 8 3 Setting close travel limit 9 8 4 Setting open travel limit 9 8 5 Automatic limit adjustment and load profile 9 8 6 Pedestrian access position 9 8 7 Errors during setting of travel limit 9 8 8 Recalculate Force Margins 9 9 Safety Obstruction Force Test 10 9 1 Testing Close Cycle 10 9 2 Testing Open Cycle 10 9 3 Force Pressur...

Страница 3: ...e an object obstructing the gateway some force must be exerted on the object As a result the object gate and or person may suffer damage or injury Regularly check to make sure that the Safety Obstruction Force is working correctly and is tested and set as per Section 12 of this manual Failure to follow these instructions could result in serious personal injury and or property damage This test must...

Страница 4: ...4 05 06 07 08 09 10 11 12 Fig 2 1 PED N O input terminal 0V V OUT 2 optional relay module coil drive V OUT 1 N C relay contact Engage sensor microswitch input Console Previous button Console Up Open button Console Next button 13 Console Exit button Console Down Close button Console SET button Antenna connector Console display PG3 programmer network connector Motor connector 24VAC input connector 1...

Страница 5: ... use these cables for any other purpose IMPORTANT WARNING A qualified electrician must perform the installation where 240V AC power is used 4 5 6 3 3 Initial Checking Before commencing installation of the NeoSlider check the following a The gate moves freely and easily by hand for the full opening and closing travel b The mounting point must be solidy constructed e g concrete brick or steel and mu...

Страница 6: ...tic Technology rack the distance is 78mm Otherwise if using a non Automatic Technology rack add your rack width and spacers if required to the 38mm see Fig 4 1 c Place the metal base plate 3 and Drive unit 1 in position If satisfied with the position remove the Drive Unit and metal base plate Fig 4 2 d Mark the position of the four holes in the metal base plate 3 Drill the four holes e Hammer the ...

Страница 7: ...facing upwards and putting it into mesh with the racks being joined Fig 5 2 f Tighten the racks This will ensure that the NeoSlider pinion can run along the racks without obstruction Rack width Gate Rack Drive gear Datum line To top of pinion To bottom of rack tooth Maximum height of rack Fig 5 1 Fig 5 2 Screws and washers Actuator Start Fig 5 3 5 2 Fixing limit actuator to rack a Manually open th...

Страница 8: ...installed might not give safety protection at all times Check to make sure that the height of the beam and type used give maximum protection possible WARNING Tampering with Safety Beams could result in serious personal injury and or property damage and will void the warranty 7 1 Installation of Safety Beams to the NeoSliderTM a Follow the Installation Manual provided with the Safety Beam to correc...

Страница 9: ...desired limit positions In order to use a transmitter it must first have at least one of its buttons coded to the gate controller The function assigned to the transmitter s buttons is of no concern here as the buttons are temporally assigned to OPEN CLOSE and SET Fig 8 1 Fig 8 1 Button 1 Inch Open Button 4 Inch Close Button 2 Set 8 1 Setting Travel Limits Navigating to code transmitter menu a Pres...

Страница 10: ...during setup Adjusting this is normally only necessitated by environmental conditions such as windy or dusty areas and areas with extreme temperature changes 9 3 Force Pressure For Close and Open Cycle Navigating To Current Trips a Press NEXT or PREV to navigate to Menu 2 Current Trips b Press SET Fig 9 2 c MENU 2 1 CLOSE Margin is displayed Fig 9 3 d Press UP arrow to increase or DOWN arrow to de...

Страница 11: ... Available functions VAC Vacation Mode LGT Courtesy Light STP Stop OPN Open CLS Close SWP Swipe PED Pedestrian access OSC Open Stop Close OFF No action Press SET to save the settings or STOP to abort without saving 10 3 Returning To Main Screen Press EXIT to return to the MAIN SCREEN and test the transmitter NOTE To edit the other settings refer to transmitter edit procedure in Appendix F 123 ID N...

Страница 12: ...osition time Fig 14 1 b Press SET to record new time c Press transmitter coded for pedestrian function to test 12 2 Pedestrian Position Set The controller will return to the MAIN SCREEN with the gate status shown as being in pedestrian access mode Fig 14 2 12 3 Error Displays During the above procedure many error checks are performed If an error is detected a message will be displayed indicating t...

Страница 13: ...m triggered status so that the Safety Beam input must be activated again before the countdown will start As with the other Safety Beam modes the STP input will abort countdown and the OPN and SWP inputs will restart the countdown if the gate is OPEN 13 Auto Close Mode 13 3 Pedestrian Auto Close Menu 3 3 Safety Beam Auto Close This mode is selected by entering a non zero time for the Safety Beam Au...

Страница 14: ...o the gate and behave differently on open cycles to that on close cycles a Press NEXT or PREV on the wall control unit to navigate to Menu 4 Lock Times b Press SET to select the sub menu c Press NEXT or PREV to navigate through the sub menu d Press OPEN to increase or CLOSE to decrease the time e Press SET to save the new time f Press the EXIT button two times to exit and test the locks operation ...

Страница 15: ...l batteries will have other environmental and social benefits Some batteries are less toxic but hazardous for other reasons Lithium batteries can explode or catch fire in landfill while button cells are dangerous if swallowed by children Recycling offers a safe and environmentally responsible solution for end of life batteries Battery recycling recovers non renewable materials such as lead cadmium...

Страница 16: ... billion random codes Over 100 billion random codes Code generation Non linear encryption algorithm Non linear encryption algorithm Transmitter battery CR2032 CR2032 NOTE 1 Measurements made at 240Vac 2 The maximum gate size that the NeoSlider NES 500 can be installed on is 10m wide and 500kg and the NeoSlider NES 800 can be installed on is 10m wide and 800kg The gate must be well balanced A perso...

Страница 17: ... display V3 Contact dealer for support if otherwise Flat battery in transmitter Replace battery Section 15 Antenna behind structure gate or fence or not in line of sight Ensure Antenna is in line of sight Section 5 2 Gate does not close with transmitter Safety Beam not working properly Make sure Safety Beams are operational and no dirt is on the lens Gate will not close fully Gate limit positions ...

Страница 18: ...ff 3 9 15 4 Menu 4 Lock Times OPEN LOCK TIME Set the time the lock is activated for on open cycles 0 0 Hold 0 5 0 1 Sec 4 1 16 1 CLOSE LOCK TIME Set the time the lock is activated for on close cycles 0 0 Hold 0 5 0 1 Sec 4 2 16 1 PRE OPEN LOCK TIME Time the lock is activated for prior to opening 0 0 25 5 0 0 0 1 Sec 4 3 16 1 PRE CLOSE LOCK TIME Time the lock is activated for prior to closing 0 0 2...

Страница 19: ...function On On 7 8 Appendix C VACATION MODE Selects vacation mode disables remote control Off Off 7 9 Appendix C BATTERY SOLAR MODE Selects Battery Backup Solar operation BATTERY ENABLED SOLAR ENABLED BATTERY ENABLED 7 10 Appendix C PASSWORD Selects password protection for all changes Off Off 7 11 Appendix C TX GROUPING Selects transmitter number group display format Off Off 7 12 Appendix C OUTPUT...

Страница 20: ...to the required sub menu d Press OPEN CLOSE to enter Edit mode and change parameter setting Fig B 2 e Holding the button down causes the parameter s value to change rapidly The longer the button is held the faster the value changes f Press SET to SAVE setting Reload Default Setting g Press NEXT PREV buttons to display LOAD DEFAULT screen h Press SET to load the default value Return To Menu If the ...

Страница 21: ...CESSORIES OV Limits Motor C O Com 1 2 MSI 1 00 Board Limits Motor C O Com 1 2 MSI 1 00 Board ATA DCB 05V2 150VA Red Black White Blue Orang e Black White Orang e Red Blue Fig C 1 This section illustrates how to wire two NeoSlider slave units into a DCB 05V3 Fig C 1 NOTE When setting limits if both openers are travelling in different directions i e one is opening and the other is closing then do the...

Страница 22: ... This parameter can be used to disable the feature for security or transmitter management reasons Menu 7 9 Vacation Mode Vacation mode blocks all but one designated remote transmitter from activating the NeoSlider The mode is activated by pressing a transmitter button with the VAC function assigned until the console displays that vacation mode is enabled approx 5 secs When activated any transmitte...

Страница 23: ...D or serial numbers are to be displayed The NeoSlider will then beep each time a transmission is received If the transmitter button is stored in the NeoSlider memory and has a function assigned to it a second screen will be displayed that shows the transmitter details along with the button pressed Fig E 4 The example shows the case where transmitter number 12 is activated by button 4 Note ID is se...

Страница 24: ...ws the OPEN CYCLE event counter with a value of 1234 When finished viewing press EXIT 1 Open Cycles 2 Close Cycles 3 PED Cycles 4 Setup Limits 5 Comm s Loss 6 Sync Faults 7 Overlaps 8 M1 Open Stall 9 M1 Close Stall 10 M1 Open Obstuctions 11 M1 Close Obstuctions 12 M1 Open Overloads 13 M1 Close Overloads 14 M1 PWM Sync Faults 15 M1 PWM Drive Faults 16 M1 Direction Faults 17 M1 Sensor Faults The Mem...

Страница 25: ...eft or right and between the top and bottom lines to select the desired field b Press UP or DOWN arrows to change the displayed value The available functions are shown below Selecting OFF will prevent the opener responding to that button Available functions VAC Vacation Mode LGT Courtesy Light STP Stop OPN Open CLS Close SWP Swipe PED Pedestrian access OSC Open Stop Close OFF No action c Press SET...

Страница 26: ...R PROCEDURE for each transmitter to be coded Coding is terminated by pressing the EXIT button Exiting The List To exit the transmitter list simply press EXIT to return to the Code menu H Transmitter Managment Appendix 14 ID B B SMITH OSC PED LGT VAC PRESS PRESS Press Tx er Button LIST PRESS Press Tx er Button LIST PRESS NOTE When a transmitter is remotely coded its ID label is set to that of the e...

Страница 27: ...g from a excessive wear and tear that may cause the product to fail b accidental deliberate or negligent damage or damage cause by nsects dirt plants or other objects c blown fuses electrical surges power surges or power spikes or faulty or unsuitable electrical wiring of structures to which the product is affixed d theft fire flood rain water lightning storms or any other acts of God e salt or ot...

Страница 28: ...omatic Technology Australia Pty Ltd No part of this document may be reproduced without prior permission In an ongoing commitment to product quality we reserve the right to change specification without notice Automatic Technololgy Australia Pty Ltd ABN 11 007 125 368 6 8 Fiveways Boulevard Keysborough Victoria 3173 Australia P 1300 133 944 E sales automatictechnology com au www automatictechnology ...

Отзывы: