![Automatic Technology NeoSlider TrioCode 128 NES-500 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/automatic-technology/neoslider-triocode-128-nes-500/neoslider-triocode-128-nes-500_manual_3021676006.webp)
6
Owner Installation Instructions
NeoSlider
TM
- Sliding Gate Opener NES-500 / NES-800
4. Drive Unit Installation
Fig 4.1
1~2mm
>115
Fig 4.2
4.1 Mounting the Drive Unit
The NeoSlider™ mounting holes are slotted for
fine adjustment of pinion gear and gate rack
alignment. Follow the procedure below to ensure
final adjustments can be made later.
a. Prior to mounting the NeoSlider™, determine
the distance from the gate to the outer edge of
the rack (i.e. the rack width) and to the datum line
(see Fig. 4.1 and Fig. 5.1
)
. If using an Automatic
Technology plastic rack, the width is 40mm. If
using a different brand of rack, please ensure it is
Module 4 and then confirm the width, as this will
vary.
b. Mark a line parallel to the face of the gate for the
mounting holes. The distance from the gate is
determined by the formula (38mm + Rack Width).
Therefore, if using an Automatic Technology
rack, the distance is 78mm. Otherwise, if using
a non-Automatic Technology rack, add your rack
width (and spacers if required) to the 38mm
(see Fig. 4.1)
.
c. Place the metal base plate
3
and Drive unit
1
in position. If satisfied with the position,
remove the Drive Unit and metal base plate
(Fig. 4.2)
.
d. Mark the position of the four holes in the metal
base plate
3
. Drill the four holes.
e. Hammer the dynabolts
4
into position, place
metal base plate and fix with the four washers,
spring washers and nuts
4
.
f. Put Drive unit
1
onto metal base plate and affix
with bolts and washers provided. Remember
when tightening the bolts to allow fine adjustment
of the NeoSlider™ later on.
4.2 Installing antenna
Mount the antenna
6
at or above the height of the
gate or fence (whichever is higher) for optimal
reception.
Do not cut the coaxial cable.
The Automatic Technology
NeoSlider™
sliding gate opener is designed to operate most residential sliding gates. The
gates must be in good working condition and should operate freely by hand. (Refer to 3.1 Initial Checking)