2.2. Connection steps
Note
: IT networks knowledge is necessary to fulfill the following:
1. Connect the lanes to the network:
according to the principle described in the previous chapter,
according to the instructions given in the lane manual (available connector type, location
and setting),
during lane installation (to pass the cables)!
For information:
1.
The master housing of each lane is equipped with a RJ45 Ethernet port
(*)
.
(*)
If the SmartLane are equipped with the
IP interface for SmartLane 9xx
option (= Ethernet/RS232 converter),
necessary for linking to the supervision panel.
(*)
If the SL93x and PPV gates are equipped with the
IP interface for SL93x/PPV
option
(= specific CPU board
n°25), necessary for linking to the supervision panel.
2. Foresee 1 Ethernet link cable per lane, except for 2 SL93x or PPV facing each other and
opening simultaneously, for which both housings must be connected to the supervision
panel.
2. Set the lanes on the network (IP address, etc.).
SlimLane
refer to the gate Maintenance Interface manual
.
SL93x + PPV323
refer to the Maintenance Interface chapter in the gate manual.
SmartLane CE
refer to the MOXA module configuration procedure
.
SmartLane UL
refer to the procedure established by Automatic Systems America
.
SmartLane 935
refer to the WAGO module configuration procedure.
3. Connect the Smart n' Slim server to the network by means of one of the 2 available ports
(PORT 1 & 2, adjustable through
The most common procedure is the following:
Connect a PC to PORT 1 of the server (
IP address 192.168.0.1 and subnet mask
255.255.255
) or connect a keypad to the server.
Connect to supervisor (
Set PORT 0 of the server for the same network than the gates (
IP address 192.168.0.2,
subnet mask 255.255.255 and default gateway 192.168.0.2
page
.
Disconnect the PC / screen and connect the server to the network by means of LAN1
port.
4. Connect to the supervisor (
page).
5. Add the new lanes to the supervisor and
assign them to a group
(
6. Configure the lanes (