MAINTENANCE
•
All maintenance work on the equipment must be carried out in
accordance with the requirements in the safety warnings in chapter 1.
•
The ground wires must interconnect all moving metallic parts (not
bolted to the frame).
Special attention should be paid during disassembly of these elements
so as not to damage the wires.
It is imperative to reconnect them during reassembly.
R
ECOMMENDED TORQUE
Recommended torque for tightening screws and nuts, unless otherwise specified:
Type of
screw
Torque (Nm)
Type of
screw
Torque (Nm)
M2
0.32
M10
43
M3
1.15
M12
75
M4
2.65
M14
119
M5
5.2
M16
182
M6
8.9
M18
250
M7
14.5
M20
355
M8
22
M22
480
O
PENING THE EXTENSION COVER
Remove the two screws that fasten the extension cover to the frame of the equipment and tilt the cover
forward until the safety cable that retains the cover on the frame is fully extended.